Failure of an uncemented non-porous metal-backed prosthesis with augmentation using impacted allograft for acetabular revision 12- to 17-year results.
نویسندگان
چکیده
We have reviewed 29 patients (30 hips) who had undergone revision total hip arthroplasty using a Freeman metal-backed acetabular component and acetabular impaction allografting. The mean follow-up was for 153 years (12 to 17). Five patients (5 hips) died with the prosthesis in situ and four (4 hips) were lost to follow-up. Twelve hips had failed and in the remaining nine there were minor symptoms. The mean time to failure requiring further surgery was nine years. Excluding patients who were lost to follow-up or had died, 72% of the hips were radiologically loose at the last review. The commonest pattern in those requiring revision was failure of the reinforcement ring in adduction with remodelling of the medial wall. Of the nine patients who had not undergone revision, one with bilateral replacements had no current radiographs and only three of the remaining seven replacements had no radiological signs of loosening. The short-term results for this technique have been reported to be satisfactory, but in the long term they are not. The factors associated with failure include the design of the prosthesis, which has been implicated in disappointing long-term results when used in primary arthroplasty, but not with the frequency of failure found in this series. It seems that the reliance on peripheral screw fixation over a bed of allograft without bridging the graft does not provide sufficient stability to allow incorporation of the graft.
منابع مشابه
Acetabular revision with morsellised allogenic bone graft and a cemented metal-backed component.
Failure of total hip arthroplasty with acetabular deficiency occurred in 55 patients (60 hips) and was treated with acetabular revision using morsellised allograft and a cemented metal-backed component. A total of 50 patients (55 hips) were available for clinical and radiological evaluation at a mean follow-up of 5.8 years (3 to 9.5). No hip required further revision of the acetabular component...
متن کاملFailure rates for 4762 revision total hip arthroplasties in the Norwegian Arthroplasty Register.
We present the results for 4762 revision total hip arthroplasties with no previous infection in the hip, which were reported to the Norwegian Arthroplasty Register between 1987 and 2003. The ten-year failure rate for revised prostheses was 26% (95% CI 25 to 26). Cox regression analyses were undertaken separately for acetabular and femoral revision components. Cemented revision components withou...
متن کاملTwenty-year survival of a cementless revision hip arthroplasty using a press-fit bulk acetabular allograft for pelvic discontinuity: a case report.
Acetabular revision in a total hip arthroplasty (THA) with pelvic discontinuity is uncommon and challenging. Optimal management remains controversial, particularly with graft and implant selection. Interpretation of outcomes is confounded by the heterogeneity of patterns of bone loss and the lack of long-term results in great numbers for any given choice of treatment. We report a revision THA u...
متن کاملIs the size of the acetabular bone lesion a predictive factor for failure in revisions of total hip arthroplasty using an impacted allograft?☆
OBJECTIVE The aim of this study was to determine the acetabular bone lesion size (in millimeters) from which impacted bone graft failure starts to occur more frequently, through simple anteroposterior hip radiographs, and whether measurement of the defect on simple radiographs maintains the same pattern in inter and intraobserver assessments. METHODS Thirty-eight anteroposterior pelvic-view r...
متن کاملMetal-backed acetabular components with conventional polyethylene: a review of 9113 primary components with a follow-up of 20 years.
The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 85 2 شماره
صفحات -
تاریخ انتشار 2003