Non-Contrast Enhanced Pulmonary Vein MRA with a Spatially Selective Inversion Preparation Sequence

نویسندگان

  • P. Hu
  • M. L. Chuang
  • T. H. Hauser
  • K. V. Kissinger
  • B. Goddu
  • L. A. Goepfert
  • N. M. Rofsky
  • W. J. Manning
  • R. Nezafat
چکیده

Introduction: Non-contrast enhanced pulmonary vein (PV) MRA is an alternative to contrast-enhanced PV imaging for assessment of PV anatomy prior to and after PV isolation as a treatment for atrial fibrillation (AF) (1,2). We propose a non-contrast enhanced three-dimensional (3D) free-breathing ECG-gated thin-slab spoiled gradient recalled echo (GRE) sequence with a slab-selective inversion for PV MRA. Methods: A sagittal inversion slab, prescribed to cover the superior and inferior vena cava and the left atrium, was applied prior to data acquisition to suppress structures adjacent to the left atrium (LA) and PVs (Figure 1). Imaging was performed using a GRE sequence after an inversion time (TI), during which the inverted (and suppressed) vena cava blood flows into the right atrium, right ventricle and pulmonary artery while the PV blood was not affected. Consequently, the conspicuity of the PV and LA was improved. The proposed method does not require signal subtraction and the inversion slab is not parallel to the imaging slab. To optimize the TI and inversion slab thickness, the proposed imaging technique was performed on 5 healthy subjects using a series of inversion time (TI) and inversion slab thickness. The TIs and thickness corresponding to the best image quality and PV/LA conspicuity were chosen as the optimal TIs and thickness, respectively. The feasibility of the proposed method was further demonstrated in a cohort of 6 additional healthy subjects. Typical imaging parameters were: TR/TE/α=3/1.4/15 ̊, TI=500 ms, FOV=300×400×60 mm, isotropic spatial resolution 1.8×1.8×1.8mm reconstructed to 0.9× 0.9×0.9 mm, 60mm inversion slab, ~550ms trigger delay, 50 views per segment, low-high view order, no parallel imaging . The slab-selective inversion pulse was an adiabatic pulse of the hyperbolic-secant shape. A 2D spiral echo beam navigator echo was positioned on the right hemi-diaphragm. A spectrally selective fat saturation pulse was applied. The contrastto-noise ratios (CNR) between the PVs/LA and the right atrium (RA), ascending aorta and pulmonary artery were measured and compared with conventional non-contrast imaging without inversion. In addition, non-contrast PV MRA was performed on 9 AF patients using the optimized sequence. The maximum PV dimension was measured in the sagittal plane using a standard method (3). The PV measurements were compared with standard contrast-enhanced PV MRA using limits of agreement analysis, standard correlation and linear regression. Results: The TI and the inversion slab thickness were optimized to be 500ms and 60mm, respectively. Compared to the conventional GRE sequence without inversion, the proposed technique greatly increased the visual conspicuity of the PVs and LA (Figure 2). The signal to noise ratios (SNR) of the PVs and the LA was similar with and without inversion (p>0.3), while the signals from the pulmonary artery and the right atrium were greatly reduced using the proposed technique (Figure 3). Figure 4 shows a comparison between non-contrast PV MRA and the clinical breath-held contrastenhanced PV MRA. There was a difference of -0.1 +/2.2 mm between the PV size measurements of contrast-enhanced PV MRA and the proposed non-contrast technique, indicating no significant bias with limits of agreement of -4.5 to 4.3. The correlation was very good at 0.91 (p<0.001). Linear regression showed a close relationship between the two measurements with a slope of 0.93 (p<0.001). Conclusions: The proposed non-contrast technique greatly enhances the conspicuity of the PVs and LA without significant loss of SNR and is promising for PV MRA of AF patients undergoing the PV isolation procedure. Acknowledgements: The authors acknowledge grant support from NIH R01EB008743-01A2, AHA SDG-0730339N, and Catalyst (Harvard Clinical and Translational Science Center). References: 1. Francois et al., Radiology 2009;250(3):932-939. 2. Krishnam et al., Invest Radiol 2009;44(8):447-453. 3. Hauser et al., J Cardiovasc Magn Reson 2004; 6(4):927-36 Figure 1: Sequence diagram (top) and illustration of imaging and inversion slabs (bottom). A slabselective inversion pulse is applied after the R-wave trigger, which is followed by an inversion time (TI) before imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-contrast-enhanced pulmonary vein MRI with a spatially selective slab inversion preparation sequence.

We propose a non-contrast-enhanced, three-dimensional, free-breathing, electrocardiogram-gated, gradient recalled echo sequence with a slab-selective inversion for pulmonary vein (PV) MRI. A sagittal inversion slab was applied prior to data acquisition to suppress structures adjacent to the left atrium (LA) and PVs, thereby improving the conspicuity of the PV and LA. Compared with other MR angi...

متن کامل

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla.

BACKGROUND The breathhold contrast-enhanced three-dimensional magnetic resonance angiography (MRA) using T1-weighted gradient-echo imaging sequence is the standard technique for MRA of the thorax. However, this technique is not desirable for certain patients with respiratory insufficiency, serious renal impairment, or allergy to contrast agents. The objective of this study was to optimize and e...

متن کامل

Non-contrast Enhanced Renal MR Angiography using NATIVE TrueFISP – Initial Experience for Clinical Imaging of Patients with Renovascular Disease

Introduction and Aims: Non-contrast MR angiography (NCE-MRA) using fast steady-state gradient echo imaging can provide an alternative method to the established technique of contrast enhanced MR angiography (CE-MRA) [1-3]. Non-contrast acquisitions are of particular use for imaging the renal arteries, since they can potentially circumvent the need for contrast agent administration in patients wi...

متن کامل

Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results.

BACKGROUND The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS Eight healthy volunteers (mean age 29 years) and eight patients...

متن کامل

Flow Preparation Pulse for Abdominal Non-Contrast-Enhanced MRA

M. Miyoshi, T. Tsukamoto GE Yokogawa Medical Systems, Hino, Tokyo, Japan Abstract Steady State Free Precession (SSFP) yields high blood signal image in short scanning time and it enables Non-Contrast-Enhanced MR Angiography (NCE-MRA) in abdomen. However, SSFP produces bright signal not only in artery but also in vein or stationary fluids. We propose new Flow Preparation (Flow Prep) pulse to dis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009