Multisite concordance of apparent diffusion coefficient measurements across the NCI Quantitative Imaging Network.

نویسندگان

  • David C Newitt
  • Dariya Malyarenko
  • Thomas L Chenevert
  • C Chad Quarles
  • Laura Bell
  • Andriy Fedorov
  • Fiona Fennessy
  • Michael A Jacobs
  • Meiyappan Solaiyappan
  • Stefanie Hectors
  • Bachir Taouli
  • Mark Muzi
  • Paul E Kinahan
  • Kathleen M Schmainda
  • Melissa A Prah
  • Erin N Taber
  • Christopher Kroenke
  • Wei Huang
  • Lori R Arlinghaus
  • Thomas E Yankeelov
  • Yue Cao
  • Madhava Aryal
  • Yi-Fen Yen
  • Jayashree Kalpathy-Cramer
  • Amita Shukla-Dave
  • Maggie Fung
  • Jiachao Liang
  • Michael Boss
  • Nola Hylton
چکیده

Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b-value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward uniform implementation of parametric map Digital Imaging and Communication in Medicine standard in multisite quantitative diffusion imaging studies.

This paper reports on results of a multisite collaborative project launched by the MRI subgroup of Quantitative Imaging Network to assess current capability and provide future guidelines for generating a standard parametric diffusion map Digital Imaging and Communication in Medicine (DICOM) in clinical trials that utilize quantitative diffusion-weighted imaging (DWI). Participating sites used a...

متن کامل

Toward Precision and Reproducibility of Diffusion Tensor Imaging: A Multicenter Diffusion Phantom and Traveling Volunteer Study.

BACKGROUND AND PURPOSE Precision medicine is an approach to disease diagnosis, treatment, and prevention that relies on quantitative biomarkers that minimize the variability of individual patient measurements. The aim of this study was to assess the intersite variability after harmonization of a high-angular-resolution 3T diffusion tensor imaging protocol across 13 scanners at the 11 academic m...

متن کامل

Multi-system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice-water phantom.

PURPOSE To determine quantitative quality control procedures to evaluate technical variability in multi-center measurements of the diffusion coefficient of water as a prerequisite to use of the biomarker apparent diffusion coefficient (ADC) in multi-center clinical trials. MATERIALS AND METHODS A uniform data acquisition protocol was developed and shared with 18 participating test sites along...

متن کامل

QIN DAWG Validation of Gradient Nonlinearity Bias Correction Workflow for Quantitative Diffusion-Weighted Imaging in Multicenter Trials

Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independen...

متن کامل

MR Scanner Systems Should Be Adequately Characterized in Diffusion-MRI of the Breast

Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of medical imaging

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2018