Preventing surgical complications: A survey on surgeons' perception of intra-articular malleolar screw misplacement in a cadaveric study

نویسندگان

  • Vincenzo Giordano
  • Arthur FS Gomes
  • Ney P Amaral
  • Rodrigo P Albuquerque
  • Robinson ES Pires
چکیده

BACKGROUND Intra-articular hardware penetration can occur during osteosynthesis of ankle fractures, jeopardizing patients' outcomes. The intraoperative recognition of misplaced screws may be difficult due to the challenge of adequate interpretation of specific radiographic views. The present study was designed to investigate the diagnostic accuracy of standardized radiographic ankle views to determine the accuracy of diagnosis for intra-articular hardware placement of medial malleolar screws in a cadaveric model. METHODS Nine preserved human cadaveric lower extremity specimens were used. Under direct visualization, two 4.0 mm cancellous screws were inserted into the medial malleolus. Each specimen was analyzed radiographically using antero-posterior (AP) and mortise views. The X-rays were randomly uploaded on a CD-ROM and included in a survey submitted to ten selected orthopaedic surgeons. The "Standards for Reporting of Diagnostic Accuracy" (STARD) questionnaire was used to determine the surgeons' perception of accuracy of screw placement in the medial malleolus. The selection of items was based on evidence whenever possible, therefore the "inconclusive" category was added. Inter and intraobserver variations were analyzed by kappa statistics to measure the amount of agreement. RESULTS There was a poor level of agreement (kappa 0.4) both in the AP and in the mortise view among all the examiners. Associating the two x-rays, the agreement remained poor (kappa 0.4). In the cases in which there was a diagnosis of articular penetration, there was a poor agreement related to which of the screws was intra-articular. The number of "inconclusive" responses was low and constant, without a statistically significant difference between the subspecialists CONCLUSION The routine intraoperative radiographic imaging of the ankle is difficult to interpret and unreliable for detection of intra-articular hardware penetration. We therefore recommend to reposition medial malleolar screws intraoperatively if there is any doubt regarding inadequate screw placement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DISPLACED- COMMINUTED INTRAARTICULAR FRACTURES OF THE ADULT DISTAL HUMERUS: FUNCTIONAL RESULTS AFTER INTERNAL FIXATION

Background: Intra-articular T- type or Y- type fractures of the distal end of the humerus are relatively rare, and consequently few surgeons will be able to attain extensive experience with the surgical treatment of these injuries. The current emphasis is on operative intervention with rigid internal fixation and early mobilization. Methods: In this prospective and retrospective study, we r...

متن کامل

Comparison of the efficacy of surgical and non-surgical treatments in intra-articular calcaneal fracture

Calcaneal fracture accounts for 2% of all fractures and is the most common tarsal fracture. Regarding this, the present study was conducted to determine and compare the surgical and non-surgical treatments in adult patients with calcaneal fractures in terms of outcomes, patients’ satisfaction level, and complications. This clinical trial was conducted on 63 patients with intraarticular fracture...

متن کامل

Surgical treatment results of acute acromioclavicular injuries

  Abstract   Background: Different methods of surgical treatment for acromioclavicular(AC)   joint injury were considered in the literature. The purpose of the study was to compare intra- articular AC repair technique with the extra-articular coracoclavicular repair technique for the patients with Rockwood type III and VAC joint injury when indicated.   Methods: Nineteen consecutive patients wi...

متن کامل

Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures

BACKGROUND Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, wh...

متن کامل

Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study

BACKGROUND The importance of the tip-apex distance (TAD) to predict the cut-out risk of fixed angle hip implants has been widely discussed in the scientific literature. Intra-operative determination of TAD is difficult and can be hampered by image quality, body habitus, and image projection. The purpose of this paper is to evaluate, through a cadaveric study, a novel computer assisted surgery s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011