Phase Sensitive Reconstruction for Water/Fat Separation in MR Imaging Using Inverse Gradient

نویسندگان

  • Joakim Rydell
  • Hans Knutsson
  • Johanna Pettersson
  • Andreas Johansson
  • Gunnar Farnebäck
  • Olof Dahlqvist Leinhard
  • Peter Lundberg
  • Fredrik Nyström
  • Magnus Borga
چکیده

This paper presents a novel method for phase unwrapping for phase sensitive reconstruction in MR imaging. The unwrapped phase is obtained by integrating the phase gradient by solving a Poisson equation. An efficient solver, which has been made publicly available, is used to solve the equation. The proposed method is demonstrated on a fat quantification MRI task that is a part of a prospective study of fat accumulation. The method is compared to a phase unwrapping method based on region growing. Results indicate that the proposed method provides more robust unwrapping. Unlike region growing methods, the proposed method is also straight-forward to implement in 3D.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three dimensional phase sensitive reconstruction for water/fat separation in MR imaging using inverse gradient

INTRODUCTION: Inand out-of-phase imaging is a useful tool in quantitative imaging of fat. Several approaches have been implemented to improve the original two point Dixon method [1], often by introducing an extra point to increase the reliability of the reconstruction hence increasing scan time. Recent papers have shown promising results with two point protocols [2,3] although in our experience...

متن کامل

Water Fat Separation with Undersampled TSE BLADE Based on Three Point Dixon

Introduction In the three-point Dixon water fat separation method, one in-phase echo and two out-of-phase echoes are sampled in Cartesian k-space trajectory conventionally [1][2]. The Cartesian sampling is sensitive to motions, such as from pulsation and flow, which cause artifacts degrading the image quality. To address this problem, a non Cartesian sampling method, TSE BLADE three-point Dixon...

متن کامل

Robust Multicoil Reconstruction for Phase-Sensitive Fat-Water Separation

Introduction: Phase-sensitive (PS) SSFP [1,2] is an efficient fat/water separation method, successfully used in several applications including angiography [1], musculoskeletal [3] and abdominal [4] imaging. It generates and detects a 180 phase-difference between fat and water. In previous work, water images reconstructed from individual coils with PSSSFP were combined [4,5]. However, abrupt spa...

متن کامل

Spiral water-fat imaging with integrated off-resonance correction on a clinical scanner.

PURPOSE To integrate water-fat-resolved spiral gradient-echo imaging with off-resonance correction into a clinical MR scanner and to evaluate its basic feasibility and performance. MATERIALS AND METHODS Three-point chemical shift imaging was implemented with forward and strongly T(2)*-weighted reverse spiral sampling and with off-resonance correction after water-fat separation. It was applied...

متن کامل

Separation of Water and Fat Magnetic Resonance Imaging Signals Using Deep Learning with Convolutional Neural Networks

Purpose: A new method for magnetic resonance (MR) imaging water-fat separation using a convolutional neural network (ConvNet) and deep learning (DL) is presented. Feasibility of the method with complex and magnitude images is demonstrated with a series of patient studies and accuracy of predicted quantitative values is analyzed. Methods: Water-fat separation of 1200 gradient-echo acquisitions f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 10 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2007