Electrostatic potential generated during extracorporeal pump prime circulation before cardiopulmonary bypass initiation.
نویسندگان
چکیده
The development of electrostatic potentials generated during cardiopulmonary bypass (CPB) procedures using polyvinylchloride (PVC) tubing in conjunction with roller pumps has been previously documented. The resulting damage from the electrostatic discharge (ESD) has been reported to affect gas transfer devices, but details of potential damage to electronic components commonly used during extracorporeal circulation have not been similarly described. The purpose of this study was to measure the ability of a triboelectric potential to be generated from a primed, circulating, adult CPB pump before the initiation of CPB. Two identical adult CPB circuits were assembled: one incorporating a roller pump and the second incorporating a centrifugal pump mechanism. Primed pumps were circulated (1-6 LPM), and evidence of generated triboelectric potentials was evaluated using a digital multimeter (Fluke 8062 A). The ESD generated from an adult CPB circuit using a roller head configuration elicited a charge in excess of 600 DC V. An identical circuit constructed with a centrifugal pump mechanism did not produce any measurable charge. Sensitive electrical components in the CPB hardware platform may be damaged by ESD potential spikes of this magnitude. Preventative measures, such as circuit charge dissipation, may reduce the potential for such damage when using PVC tubing.
منابع مشابه
The effects of conventional extracorporeal circulation versus miniaturized extracorporeal circulation on microcirculation during cardiopulmonary bypass-assisted coronary artery bypass graft surgery.
OBJECTIVES To reduce the complications associated with cardiopulmonary bypass (CPB) during cardiac surgery, many modifications have been made to conventional extracorporeal circulation systems. This trend has led to the development of miniaturized extracorporeal circulation systems. Cardiac surgery using conventional extracorporeal circulation systems has been associated with significantly redu...
متن کاملComparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries
Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...
متن کاملImpact of extracorporeal circuit prime volume reduction on whole blood sequestration during acute normovolemic hemodilution for adult cardiac surgery patients.
Acute normovolemic hemodilution (ANH) is a blood-conservation method in which whole blood (WB(ANH)) is sequestered into blood collection bags before the commencement of surgery. However, for cardiac surgery, extracorporeal circuit (ECC) priming techniques limit the amount of blood that may collected prior to the actual initiation of cardiopulmonary bypass (CPB). In this study, computational mod...
متن کاملEffect of cardiopulmonary bypass on a patient with endocarditis and malaria.
Knowledge about the effects of cardiopulmonary bypass on malarial patients is scant. Malaria-induced hemolysis can exercerbate by performing extracorporeal circulation on a patient infected with Plasmodium and may, therefore, lead to a critical hemolysis jeopardizing the clinical outcome. A 52-year-old patient suffering from malaria and endocarditis was scheduled for urgent aortic valve replace...
متن کاملMyocardial Revascularization without Extracorporeal Circulation; Why Hasn’t It Convinced Yet?
Extracorporeal circulation has led to a great development in cardiovascular surgery during the last five decades. Its time-proven efficacy and safety have made on-pump coronary artery bypass grafting (CABG) the gold standard method of surgical revascularization. However, coronary revascularization on cardiopulmonary bypass and the accompanying aortic manipulation are related to plenty of delete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2007