New Applications for the Touchscreen in 2D and 3D Medical Imaging Workstations
نویسندگان
چکیده
We present a new interface technique which augments a 3D user interface based on the physical manipulation of tools, or props, with a touchscreen. This hybrid interface intuitively and seamlessly combines 3D input with more traditional 2D input in the same user interface. Example 2D interface tasks of interest include selecting patient images from a database, browsing through axial, coronal, and sagittal image slices, or adjusting image center and window parameters. Note the facility with which a touchscreen can be used: the surgeon can move in 3D using the props, and then, without having to put the props down, the surgeon can reach out and touch the screen to perform 2D tasks. Based on previous work by Sears, we provide touchscreen users with visual feedback in the form of a small cursor which appears above the finger, allowing targets much smaller than the finger itself to be selected. Based on our informal user observations to date, this touchscreen stabilization algorithm allows targets as small as 1.08 mm x 1.08 mm to be selected by novices, and makes possible selection of targets as small as 0.27 mm x 0.27 mm after some training. Based on implemented prototype systems, we suggest that touchscreens offer not only intuitive 2D input which is well accepted by physicians, but that touchscreens also offer fast and accurate input which blends well with 3D interaction techniques.
منابع مشابه
Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملDesign and Manipulation 3D Imaging System by using Photodiode Grid
Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...
متن کاملA New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT
ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance. In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011