UK Fixation of Distal Tibia Fractures (UK FixDT): protocol for a randomised controlled trial of ‘locking’ plate fixation versus intramedullary nail fixation in the treatment of adult patients with a displaced fracture of the distal tibia
نویسندگان
چکیده
INTRODUCTION The treatment of displaced, extra-articular fractures of the distal tibia remains controversial. These injuries are difficult to manage due to limited soft tissue cover, poor vascularity of the area and proximity to the ankle joint. Surgical treatment options are expanding and include locked intramedullary nails, plate and screw fixation and external fixator systems. The nail and plate options are most commonly used in the UK, but controversy exists over which treatment is most clinically and cost-effective. In this multicentre randomised controlled trial we aim to assess ratings of disability 6 months postinjury in patients who have sustained a distal tibia fracture treated with either an intramedullary nail or plate and locking screw fixation. METHODS AND ANALYSIS Adult patients presenting at trial centres with an acute fracture of the distal tibia will be considered for inclusion. A total of 320 patients will provide 90% power to detect a difference of 8 points in Disability Rating Index (DRI) score at 6 months at the 5% level. The randomisation sequence is stratified by trial centre and age, and administered via web-based service with 1:1 treatment allocation. Baseline demographic and pre-injury functional data and radiographs will be collected using the DRI, Olerud and Molander, and EuroQol EQ-5D questionnaire. Clinical assessment, early complications and radiographs will be recorded at 6-8 weeks. Functional outcome, health-related quality of life and resource use will be collected at 3, 6 and 12 months postoperatively. The main analysis will investigate differences in DRI 6 months postsurgery, between the two treatment groups, on an intention-to-treat basis. Tests will be two-sided and considered to provide evidence for a significant difference if p values are <0.05. ETHICS AND DISSEMINATION NRES Committee West-Midlands, 6/11/2012 (ref:12/WM/0340). The results of the trial will be disseminated via peer-reviewed publications and presentations at relevant conferences. TRIAL REGISTRATION NUMBER ISRCTN99771224.
منابع مشابه
Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملThe use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملUnion Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures
Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...
متن کاملMinimally Invasive Plate Versus Intramedullary Interlocking Nailing In Distal Third Tibia Fractures
Prospective study of sixty patients with distal tibia fracture who underwent surgical fixation at Sri Ramachandra University between June 2010 -June 2013. Of the 60 patients included in our study 30 underwent closed intramedullary interlocking nail and 30 were treated with plate osteosynthesis (MIPO). Patients were followed up for clinical and radiological evaluation using modified Klernn and B...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -