Abstract Power systems are subjected to a wide range of small or large disturbances during operating conditions. Power system disturbances such as line switching, generator disconnection and sudden removal of faults causes oscillations in an electrical machine rotor angles that can result in severe power swings. Depending on the protection controls, the system may remain stable or unstable and it may result in loss of synchronism. In recent years, distance relay finds difficulty between symmetrical fault and power swing which causes undesired tripping of the transmission line is the foremost reason for blackout. This paper proposes a new method Park’s Transformation and Fast Fourier Transform which are used to discriminate between the three phase fault and power swing and also to protect the backup zone of distance relay. This method is verified for normal and abnormal conditions with different load angles and different fault locations in IEEE 6-bus system are simulated in MATLAB/ Simulink. The Simulation results show the capability to avoid unwanted tripping decision of relay quickly and precisely.
منابع مشابه
Improved Symmetrical Fault Detection Scheme during Power Swing
Relays may not perform as intended occasionally due to many complex reasons, which may result in relay misoperation. This paper provides a fast detection scheme for symmetrical fault during power swing based on travelling wave theory and wavelet transform. The implementation of the proposed method is discussed in detail, which covers implementation framework, data requirements, selection of mot...
متن کاملDetection of Fault in Fixed Series Compensated Transmission Line during Power Swing Using Wavelet Transform
At the time of power swing the measured impedance lies inside the relay operating region. There is undesired tripping of Distance relay during power swing without having any fault. So relay must be blocked & must trip after a fault occur during power swing. This paper presents new technique to detect fault during power swing. In the proposed technique process starts by simulating the double tra...
متن کاملSymmetrical Short Circuit Parameter Differences of Double Fed Induction Generator and Synchronous Generator Based Wind Turbine
Considering the importance of perturbations during short circuit (SC) in power conversion devices, this study designed to find out the efficacy of symmetrical short circuit (SSC) of the synchronous generator (SG) and doubly fed induction generators (DFIG). Both wind power systems were separately built (Park’s model) and simulated. Simulation results showed that the DFIG is more efficient, fault...
متن کاملInter-Turn Fault Detection in Power transformer Using Wavelets
Detection and removal of incipient faults in power transformer winding is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. This research article presenta a new, simple and incipient fault detection technique, which is based on symmetrical component approach. Using this protection technique, it is possible to detect minor turn-to-turn f...
متن کاملA Novel Fault Detection and Classification Approach in Transmission Lines Based on Statistical Patterns
Symmetrical nature of mean of electrical signals during normal operating conditions is used in the fault detection task for dependable, robust, and simple fault detector implementation is presented in this work. Every fourth cycle of the instantaneous current signal, the mean is computed and carried into the next cycle to discover nonlinearities in the signal. A fault detection task is complete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016