Detecting Stripe Artefacts in Ultrasound Parametric Images
نویسندگان
چکیده
Parametric ultrasound images visualising a patient’s brain perfusion often suffer from stripe artefacts – a darker, radially oriented image region originating from inhomogeneities in the cranial bone or the dura mater. We present an algorithm for detecting these artifacts with regard to automatic evaluation of parametric images. The algorithm exploits that stripe artefacts by virtue of their origin are always parallel to the ultrasound beam. After image preprocessing the algorithm amplifies vertical structures with a suitable filter kernel. It then continues to work on single possible stripe artefacts which are marked as such based on their average grey values in different subparts. Our results show that the algorithm recognizes stripe artefacts with an error rate of 0-7% in different images with artificial and real artefacts. Thus, it provides an important step towards automatic image evaluation since stripe artefacts are very close in their local appearance to pathological areas.
منابع مشابه
Visualization of photoacoustic images in a limited-View measuring system using eigenvalues of a photoacoustic transmission matrix
Photoacoustic imaging is a unique imaging method that involves extracting information from points at different depths, an advantage of ultrasound imaging, while maintaining functional information, a key feature of conventional photo imaging. This makes it easy to add functional images to ultrasound images by adding a laser pulse source to the conventional ultrasound imaging device and detecting...
متن کامل[Automatic detection of perfusion deficits with Bolus Harmonic Imaging].
PURPOSE The diagnosis of ischemic stroke relies increasingly on the usage of ultrasound-based methods. One of the recent methods is the transcranial, contrast agent-based Bolus Harmonic Imaging (BHI) method. The captured image sequence is manually examined by clinical experts thus resulting in a time-consuming procedure. The purpose of this study is to evaluate three different methods to analyz...
متن کاملStrain and strain rate parametric imaging. A new method for post processing to 3-/4-dimensional images from three standard apical planes. Preliminary data on feasibility, artefact and regional dyssynergy visualisation
BACKGROUND We describe a method for 3-/4D reconstruction of tissue Doppler data from three standard apical planes, post processing to derived data of strain rate/strain and parametric colour imaging of the data. The data can be displayed as M-mode arrays from all six walls, Bull's eye projection and a 3D surface figure that can be scrolled and rotated. Numerical data and waveforms can be re-ext...
متن کاملLine detection in speckle images using Radon transform and ℓ1 regularization
Boundaries and lines in medical images are important structures as they can delineate between tissue types, organs, and membranes. Although, a number of image enhancement and segmentation methods have been proposed to detect lines, none of these have considered line artefacts, which are more difficult to visualise as they are not physical structures, yet are still meaningful for clinical interp...
متن کاملStudy of Diagnosis of Pregnancy and Fetal Development by 2D Ultrasound in Markhoz Goat
Objective- The aim of this study was to obtain first time diagnosis of pregnancy and study of fetal development in different times of pregnancy period. Design- ِDescriptive study. Animals- 8 pregnant Markhoz goats. Procedure- 2D ultrasound was performed from day 25 to 130 of gestation, twice in week from day 25 to 70 and once in week from day 70 to 130 of gestation on eight goa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -