Rigid Sternal Fixation Improves Postoperative Recovery
نویسندگان
چکیده
INTRODUCTION During the past five years, ridged sternal fixation has been utilized for sternal closure after cardiac surgery. It is known that this procedure provides better sternal stability; however, its contribution to patient recovery has not been investigated. METHODS Retrospective chart review was conducted for patients who underwent CABG and/or valve surgery in our institution between 2009 and 2010. Preoperative, perioperative, and follow-up data of patients with ridgid fixation (group R, n=89) were collected and compared with those patients with conventional sternal closure (group C, n=133). The decision regarding the sternal closure method was based on the surgeon's preferences. Univariate followed by multivariate analyses were performed to evaluate the dominant factor of sternal lock usage and to evaluate postoperative recoveries. The factors included in the analyses were; age, sex, coronary risk factors, urgency of surgery, ejection fraction, coronary anatomy, preoperative stroke, renal function, and preoperative presence of heart failure. All statistical analyses were performed by JMP software. RESULTS Group R was younger (62 ± 9 in group R vs 69 ± 11 in group C, p<0.0001) than group C, more male dominant (61% vs 49%, p=0.0452), had a lower percentage of patients undergoing redo-surgery (2.2% vs 9.0%, p<0.0418), was more likely to be used in isolated coronary artery bypass grafting (71% vs 46%, p=0.0002), more often to be used for large patient (body mass index, BMI greater than 30) (58% vs 37%. P=0.0045), and patients were more likely to have a low EuroSCORE (2.6 ± 2.3 vs 4.4 ± 2.7). Intubation time (13 ± 20 hours vs 39 ± 97 hours, p=0.0030), ICU stay (58 ± 40 hours vs 99 ± 119 hours, p=0.0003), and postoperative length of stay (7.0 ± 3.7 days vs 8.4 ± 4.7 days, p<0.0141) were significantly shorter in group R than group C. Multivariate analyses showed ridged sternal fixation was the most dominant factor affecting intubation time and ICU stay. CONCLUSION Rigid sternal fixation systems were more frequently applied to low risk young male patients. Among these selected patients, ridgid sternal fixation can contribute to early patient recovery.
منابع مشابه
Treatment of traumatic sternal fractures with titanium plate internal fixation: a retrospective study
BACKGROUND This study aim to evaluate surgical procedures for titanium plate internal fixation of sternal fractures with displacement or nonunion. METHODS From January 2010 to December 2014, 64 patients with sternal fractures were treated with titanium plate internal fixation in the thoracic surgery department of the Shanghai Sixth People's Hospital. Pain severity scale scores were analyzed p...
متن کاملSternal plating for primary and secondary sternal closure; can it improve sternal stability?
BACKGROUND Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model. METHODS Midline sternotomy was performed in 1...
متن کاملMultidimensional Sternal Fixation to Overcome a “Floating” Sternum
This case report describes the repair of a complete sternal dehiscence of the lower right sternum using sternal wires, manubrial plates, and a Talon closure device for rigid, multidimensional sternal fixation. Sternal dehiscence is a rare but significant cause of morbidity for patients undergoing median sternotomy. The risk factors for this complication are well described and although sternal w...
متن کاملThe Arrowhead Ministernotomy with Rigid Sternal Plate Fixation: A Minimally Invasive Approach for Surgery of the Ascending Aorta and Aortic Root
Background. Ministernotomy incisions have been increasingly used in a variety of settings. We describe a novel approach to ministernotomy using arrowhead incision and rigid sternal fixation with a standard sternal plating system. Methods. A small, midline, vertical incision is made from the midportion of the manubrium to a point just above the 4th intercostal mark. The sternum is opened in the ...
متن کاملA Cadaveric, Biomechanical Analysis of Sternal Fixation Systems
Rigid fixation of bony structures has been introduced and implemented as a means to improve stability and reduce motion. Tight fixation has been reported as an essential factor for successful healing1. A variety of devices including plates, intramedullary nails, pedicle screws and interbody fusion devices are used in orthopaedic, spinal and cranial facial procedures to provide rigid fixation. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2011