Artifacts in magnetic measurements of fluid samples.

نویسندگان

  • Z Boekelheide
  • C L Dennis
چکیده

Applications of magnetic fluids are ever increasing, as well as the corresponding need to be able to characterize these fluids in situ. Commercial magnetometers are accurate and well-characterized for solid and powder samples, but their use with fluid samples is more limited. Here, we describe artifacts which can occur in magnetic measurements of fluid samples and their impact. The most critical problem in the measurement of fluid samples is the dynamic nature of the sample position and size/shape. Methods to reduce these artifacts are also discussed, such as removal of air bubbles and dynamic centering.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

خواص مغناطیسی نانو ذرات FeCo برای ذخیره سازی اطلاعات

  Submicron FeCo magnetic grains with different percents of cobalt were grown in the presence of magnetic field. After omitting the excess ions and oxygen, heat treatment was performed and some samples were oriented in a polymer background in the presence of a magnetic field. The results of SEM, XRD, and magnetic measurements confirm the existence of induced magnetic anisotropy. As the strength...

متن کامل

خواص ترابردی مغناطیسی واثر هال در نمونه هایGdpr-123

  Single phase polycrystalline Gd1-xPrxBa2Cu3O7-δ samples with x=0.05 , 0.10, and 0.15 have been prepared by standard solid state reaction technique and characterized by XRD and SEM analysis. The electrical resistivity, Hall effect and magnetoresistance measurements have been on the samples. The electrical resistivity measurements indicate a reduction of transition temperature (Tc) and an incre...

متن کامل

Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study

Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...

متن کامل

مطالعه اثر تهی جا در جایگاه لانتانیوم روی خصوصیات ساختاری، الکتریکی و مغناطیسی ترکیب منگنایت La1-xMnO3+δ، ساخته شده تحت شرایط متفاوت

 In this investigation, the effect of Lanthanum vacancy on the structural, electrical and magnetic properties of La1-xMnO3+δ manganite (x=0, 0.05) was studied. Decreasing La3+ amount in samples led to creation of some Mn4+ cations. By increasing the Mn4+content in atomic structure of samples, double exchange interaction was strengthened. Results of Ac magnetic susceptibility measurements indica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AIP advances

دوره 6 8  شماره 

صفحات  -

تاریخ انتشار 2016