Analytical validation of the new version of the Liaison N-Tact PTH assay.
نویسندگان
چکیده
We performed analytical validation of the new version of the Liaison N-Tact PTH (parathormone) assay according to NCCLS guidelines and compared this new generation of reagent with the Roche Elecsys PTH assay. We showed that this new version is a sensitive and precise method with good recovery. Significant carryover was observed, but with limited clinical implications. We demonstrated that the new version of the Liaison PTH is in reasonably good agreement with the Roche Elecsys PTH assay, and as we observed no differences in a hemodialyzed population, moving from one method to the other should not affect the daily follow-up of patients. However, one should be cautious with the highest values (>500 pg/mL). We established reference intervals of 12-54 pg/mL for the Liaison and 14-52 pg/mL for the Elecsys assay.
منابع مشابه
Switching between parathormone (PTH) assays: the impact on the diagnosis of renal osteodystrophy.
BACKGROUND Clinical guidelines for decision-making in chronic kidney disease (CKD) consider parathormone (PTH) levels. The measured PTH values differ if novel full length PTH(1-84) assays are used instead of earlier intact iPTH assays. In this study we analyzed how the classification of CKD patients alters when iPTH assays are switched to PTH(1-84) assays. METHODS Plasma samples were collecte...
متن کاملAssay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.
BACKGROUND The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. METHODS We studied 228 osteoporo...
متن کاملCorrelation of results between validated in-house analysis method with new pharmacopeia monograph for analysis of Sitagliptin Phosphate API
Having validated analysis methods for medicinal ingredients is attractive for pharmaceutical companies. When a new molecule is introduced to the market, there is not any pharmacopeial analysis method for that. After publishing official methods, correlation between validated in-house methods and the official one could stablish the value of the in-house method. Sitagliptin phosphate is a new anti...
متن کاملA STABLE COUPLED NEWTON'S ITERATION FOR THE MATRIX INVERSE $P$-TH ROOT
The computation of the inverse roots of matrices arises in evaluating non-symmetriceigenvalue problems, solving nonlinear matrix equations, computing some matrixfunctions, control theory and several other areas of applications. It is possible toapproximate the matrix inverse pth roots by exploiting a specialized version of New-ton's method, but previous researchers have mentioned that some iter...
متن کاملAttitudes towards English Language Norms in the Expanding Circle: Development and Validation of a new Model and Questionnaire
This paper describes the development and validation of a new model and questionnaire to measure Iranian English as a foreign language learners’ attitudes towards the use of native versus non-native English language norms. Based on a comprehensive review of the related literature and interviews with domain experts, five factors were identified. A draft version of a questionnaire based on those f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 45 1 شماره
صفحات -
تاریخ انتشار 2007