Biocompatibility of Intraocular Lenses

نویسندگان

  • Pelin Özyol
  • Erhan Özyol
  • Fatih Karel
چکیده

The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in terms of uveal biocompatibility, based on the inflammatory foreign-body reaction of the eye against the implant, and in terms of capsular biocompatibility, determined by the relationship of the intraocular lens with residual lens epithelial cells within the capsular bag. Insufficient biocompatibility of intraocular lens materials may result in different clinical entities such as anterior capsule opacification, posterior capsule opacification, and lens epithelial cell ongrowth. Intraocular lenses are increasingly implanted much earlier in life in cases such as refractive lens exchange or pediatric intraocular lens implantation after congenital cataract surgery, and these lenses are expected to exhibit maximum performance for many decades. The materials used in intraocular lens manufacture should, therefore, ensure long-term uveal and capsular biocompatibility. In this article, we review the currently available materials used in the manufacture of intraocular lenses, especially with regard to their uveal and capsular biocompatibility, and discuss efforts to improve the biocompatibility of intraocular lenses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Intraocular Lenses Surface Roughness by Atomic Force Microscopy

The aim of this study was to evaluate the surface roughness of intraocular lenses (IOLs) generated by the manufacturing process and to determine the roughness parameters of 3D surface using atomic force microscopy (AFM). Intraocular lenses commercially available from a single manufacturer: Pharmacia & Upjohn Co. were investigated. Three intraocular lenses, model 911A CeeOn Edge, were analyzed o...

متن کامل

Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD(™) lens is an aspheric, hydrophilic acrylic intraocular lens (IOL). The hydrophilic design of the lens is optimized to address dysphotopsia while maintaining biocompatibility, optical clarity, resistance to damage, and resistance to bio...

متن کامل

[Late opacification of a polymethylmethacrylate (PMMA) intraocular lens: case report].

The use of intraocular lenses was a great advance in visual recovery after cataract surgery. Although usually with good biocompatibility, some alterations in the intraocular lens material may occur after implantation. Polymethylmethacrylate was the first intraocular lens material to be used on a large scale and assumed to be inert and well-tolerated. We present a rare case of late opacification...

متن کامل

Scanning electron microscopy and energy dispersive spectroscopy findings in explanted PMMA and hydrophilic acrylic intraocular lenses.

PURPOSE To investigate the presence of calcium (Ca) aggregates influencing biocompatibility and the factors that affect calcium accumulation in explanted intraocular lenses (IOL) and to analyze the Ca distribution in an opacified hydrophilic acrylic lens. METHODS Surface irregularities and aggregates of 13 IOLs were studied with scanning electron microscopy, and their relative concentrations ...

متن کامل

Light-adjustable lens.

PURPOSE First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cyt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2017