Simultaneous determination of dopamine and carvedilol in human serum and urine by first-order derivative fluorometry.

نویسندگان

  • Huai You Wang
  • Yan Xiao
  • Juan Han
  • Xue Shun Chang
چکیده

A sensitive and selective method for simultaneous determination of carvedilol and dopamine was described. The emission wavelengths of carvedilol and dopamine were at 354 nm and 314 nm with the excitation at 290 nm, respectively. The determination of carvedilol and dopamine by normal fluorometry was difficult because the emission spectra of carvedilol and dopamine were overlapped seriously. The first derivative peaks of carvedilol and dopamine were at 336 nm and 302 nm, respectively. The linear regression equations of the calibration graphs of carvedilol and dopamine were C = 0.000557H-0.00569 and C = 0.00438H-0.0812, with the correlation coefficients were 0.9953 and 0.9988, respectively. The liner range for the determination of carvedilol was 0.002 microg ml(-1) to 0.02 microg ml(-1), and 0.05 microg ml(-1) to 0.6 microg ml(-1) for dopamine. The detection limits were 1 ng ml(-1) for carvedilol and 0.04 microg ml(-1) for dopamine, respectively. The relative standard derivative (RSD) of 4.38% and 4.35% was observed for carvedilol and dopamine, respectively. The recovery of carvedilol was from 95.00% to 106.7% in human serum and from 97.50% to 105.0% in urine sample. The recovery of dopamine was from 100.0% to 102.5% in human serum and from 97.50% to 105.0% in urine sample. This method is simple and can be used for determination of carvedilol and dopamine in human serum and urine sample with satisfactory results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous determination of carvedilol and ampicillin sodium by first-derivative fluorometry in the presence of human serum albumin.

A sensitive and selective method for the simultaneous determination of carvedilol and ampicillin sodium (AS) in the presence of human serum albumin (HSA) is described. The maximum emission wavelengths of carvedilol and AS are at 357 nm and 426 nm with excitation at 254 nm, respectively. The first-derivative peaks of carvedilol and AS were at 337 nm and 398 nm, respectively. The linear-regressio...

متن کامل

Simultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex

A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...

متن کامل

Coupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples

Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...

متن کامل

Fabrication of TiO2 Hollow Spheres and its Application in Modification of Carbon Paste Electrode For Simultaneous Determination of Dopamine and Piroxicam in the Presence of Ascorbic acid

In this work we report preparation TiO2 hollow spheres and its application as an electrochemical sensor. Therefore the novel carbon paste electrode modified with TiO2 hollow spheres (TOHS), multi-walled carbon nanotubes (MWCNTs) and poly-glutamic acid (PGA) film (PGA/TOHS/MWCNTs/CPE) was used for simultaneous determination of dopamine (DA) and piroxicam (PRX) in the presence of ascorbic acid (A...

متن کامل

Application of CuO nano particle/multi-walled carbon nanotube nanocomposite modified electrode for simultaneous determination of dopamine and rutin in real samples

Background: In this work, a new method was developed for simultaneous determination of dopamine and rutin at glassy carbon electrode modified with CuO nanoparticles doped multi-walled carbon nanotubes (CuONPs–MWNT/GCE). This modified electrode has shown excellent electrocatalytic activity toward the oxidation of rutin in acetate buffer solution (pH=5). The modified electrode lowered the overpot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2005