New method for noninvasive quantification of central venous pressure by ultrasound.

نویسندگان

  • Chang-Yang Xing
  • Yuan-Ling Liu
  • Mei-Ling Zhao
  • Rui-Jing Yang
  • Yun-You Duan
  • Lian-Hua Zhang
  • Xu-De Sun
  • Li-Jun Yuan
  • Tie-Sheng Cao
چکیده

BACKGROUND The central venous pressure (CVP) is essential for assessing the cardiac preload and circulating blood volume in clinic. The invasive CVP measurement by central venous catheter has been reported with various complications. The aim of this study was to develop a new noninvasive method for quantification of CVP by ultrasound. METHODS AND RESULTS Seventy-six patients who had their CVP monitored for intraoperative or postoperative management were recruited. By accurate location of the collapse point of the internal jugular vein and the center of the right atrium using ultrasound imaging, the height of the fluid column between those 2 points was measured as the noninvasive CVP (CVPn). A total of 118 measurements were performed and compared with the invasive CVP (CVPi). Linear correlation analysis revealed a significant correlation between CVPi and CVPn (preoperative measurements, r=0.90; P<0.01 and postoperative measurements, r=0.93; P<0.01). Bland-Altman plots showed a good agreement between CVPi and CVPn with the mean difference of 0.22 mm Hg (preoperative measurements) and -0.09 mm Hg (postoperative measurements), respectively. CONCLUSIONS The new noninvasive CVP quantification method based on the location of both the collapse point of internal jugular vein and the center of right atrium by ultrasound could be used as a reliable approach for monitoring the hemodynamic status in clinic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive central venous pressure measurement by compression ultrasound-A step into real life

Information on central venous pressure (CVP) is helpful in clinical situations like cardiac failure and sepsis. Compression ultrasound (CU) of a forearm vein has been shown to be a reliable method for CVP measurement when assessed by experienced personal under study conditions. To test the hypothesis, that CU can be reliably used for CVP measurement after a training program and using a portable...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

Measurement of Central Venous Pressure Using Ultrasound in Emergency Department

BACKGROUND In order to assessment of intravascular fluid measurement of central venous pressure (CVP) is used via central venous catheterization (CVC). This procedure is highly invasive and may cause serious complications such as pneumothorax, infection, hematoma and etc. It is so valuable procedure if we can uses a less invasive or noninvasive procedure to assess patients intravascular fluid i...

متن کامل

بررسی تأثیر استفاده از چک لیست ثبت اقدامات بر عملکرد پرستاران بخش مراقبت های ویژه در اندازه‌گیری فشار ورید مرکزی

  Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards. The purpose of this study was to evaluate the effect of using a checklist in measuring central venous pressure by nurses .   Methods & Materials: This was a nonequivalent group design on 70 nurses w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 2015