A Volumetric Method for Quantifying Atherosclerosis in Mice by Using MicroCT: Comparison to En Face

نویسندگان

  • David J. Lloyd
  • Joan Helmering
  • Stephen A. Kaufman
  • James Turk
  • Matt Silva
  • Sergio Vasquez
  • David Weinstein
  • Brad Johnston
  • Clarence Hale
  • Murielle M. Véniant
چکیده

Precise quantification of atherosclerotic plaque in preclinical models of atherosclerosis requires the volumetric assessment of the lesion(s) while maintaining in situ architecture. Here we use micro-computed tomography (microCT) to detect ex vivo aortic plaque established in three dyslipidemic mouse models of atherosclerosis. All three models lack the low-density lipoprotein receptor (Ldlr(-/-)), each differing in plaque severity, allowing the evaluation of different plaque volumes using microCT technology. From clearly identified lesions in the thoracic aorta from each model, we were able to determine plaque volume (0.04-3.1 mm(3)), intimal surface area (0.5-30 mm(2)), and maximum plaque (intimal-medial) thickness (0.1-0.7 mm). Further, quantification of aortic volume allowed calculation of vessel occlusion by the plaque. To validate microCT for future preclinical studies, we compared microCT data to intimal surface area (by using en face methodology). Both plaque surface area and plaque volume were in excellent correlation between microCT assessment and en face surface area (r(2) = 0.99, p<0.0001 and r(2) = 0.95, p<0.0001, respectively). MicroCT also identified internal characteristics of the lipid core and fibrous cap, which were confirmed pathologically as Stary type III-V lesions. These data validate the use of microCT technology to provide a more exact empirical measure of ex vivo plaque volume throughout the entire intact aorta in situ for the quantification of atherosclerosis in preclinical models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Induction of atherosclerosis by low-fat, semisynthetic diets in LDL receptor-deficient C57BL/6J and FVB/NJ mice: comparison of lesions of the aortic root, brachiocephalic artery, and whole aorta (en face measurement).

OBJECTIVE A semisynthetic diet with varying amounts of cholesterol was used to achieve hypercholesterolemia and atherosclerosis in LDL receptor-deficient (LDLR-/-) mice. Atherosclerotic lesions were measured as cross-sectional area at the aortic root and brachiocephalic artery and by en face analysis of aortic lesion area in 209 male and female animals on the C57BL/6J (B6.LDLR-/-) and FVB/NJ (F...

متن کامل

Quantitative and qualitative estimation of atherosclerotic plaque burden in vivo at 7T MRI using Gadospin F in comparison to en face preparation evaluated in ApoE KO mice

BACKGROUND The aim of the study was to quantify atherosclerotic plaque burden by volumetric assessment and T1 relaxivity measurement at 7T MRI using Gadospin F (GDF) in comparison to en face based measurements. METHODS AND RESULTS 9-weeks old ApoE-/- (n = 5 for each group) and wildtype mice (n = 5) were set on high fat diet (HFD). Progression group received MRI at 9, 13, 17 and 21 weeks after...

متن کامل

Comparison of Two Spectrophotometric Methods for Quantifying Total Hydroxycinnamic Acids in Coneflower (Echinacea purpurea) Preparations

Background & Aim: Hydroxycinnamic acids are one of the most important bioactive substances of Echinacea drugs. These compounds possess immuno-enhancing activity and thus, total hydroxycinnamic acids are mostly used as the main criterion for quality control of Echinacea purpurea and its drugs.  Hence, the quality control of Echinacea requires to develo...

متن کامل

Comparison of Two Spectrophotometric Methods for Quantifying Total Hydroxycinnamic Acids in Coneflower (Echinacea purpurea) Preparations

Background & Aim: Hydroxycinnamic acids are one of the most important bioactive substances of Echinacea drugs. These compounds possess immuno-enhancing activity and thus, total hydroxycinnamic acids are mostly used as the main criterion for quality control of Echinacea purpurea and its drugs.  Hence, the quality control of Echinacea requires to develo...

متن کامل

Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

BACKGROUND In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate and reproducible measures of tumor size in mice compared with caliper measurements. Furthermore, we evalua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011