Active surveillance for adverse events: the experience of the Vaccine Safety Datalink project.
نویسندگان
چکیده
OBJECTIVE To describe the Vaccine Safety Datalink (VSD) project's experience with population-based, active surveillance for vaccine safety and draw lessons that may be useful for similar efforts. PATIENTS AND METHODS The VSD comprises a population of 9.2 million people annually in 8 geographically diverse US health care organizations. Data on vaccinations and diagnoses are updated and extracted weekly. The safety of 5 vaccines was monitored, each with 5 to 7 prespecified outcomes. With sequential analytic methods, the number of cases of each outcome was compared with the number of cases observed in a comparison group or the number expected on the basis of background rates. If the test statistic exceeded a threshold, it was a signal of a possible vaccine-safety problem. Signals were investigated by using temporal scan statistics and analyses such as logistic regression. RESULTS Ten signals appeared over 3 years of surveillance: 1 signal was reported to external stakeholders and ultimately led to a change in national vaccination policy, and 9 signals were found to be spurious after rigorous internal investigation. Causes of spurious signals included imprecision in estimated background rates, changes in true incidence or coding over time, other confounding, inappropriate comparison groups, miscoding of outcomes in electronic medical records, and chance. In the absence of signals, estimates of adverse-event rates, relative risks, and attributable risks from up-to-date VSD data have provided rapid assessment of vaccine safety to policy-makers when concerns about a specific vaccine have arisen elsewhere. CONCLUSIONS Care with data quality, outcome definitions, comparison groups, and length of surveillance are required to enable detection of true safety problems while minimizing false signals. Some causes of false signals in the VSD system were preventable and have been corrected, whereas others will be unavoidable in any active surveillance system. Temporal scan statistics, analyses to control for confounding, and chart review are indispensable tools in signal investigation. The VSD's experience may inform new systems for active safety surveillance.
منابع مشابه
Near real-time surveillance for influenza vaccine safety: proof-of-concept in the Vaccine Safety Datalink Project.
The emergence of pandemic H1N1 influenza in 2009 has prompted public health responses, including production and licensure of new influenza A (H1N1) 2009 monovalent vaccines. Safety monitoring is a critical component of vaccination programs. As proof-of-concept, the authors mimicked near real-time prospective surveillance for prespecified neurologic and allergic adverse events among enrollees in...
متن کاملPractice of Epidemiology Near Real-Time Surveillance for Influenza Vaccine Safety: Proof-of-Concept in the Vaccine Safety Datalink Project
The emergence of pandemic H1N1 influenza in 2009 has prompted public health responses, including production and licensure of new influenza A (H1N1) 2009 monovalent vaccines. Safety monitoring is a critical component of vaccination programs. As proof-of-concept, the authors mimicked near real-time prospective surveillance for prespecified neurologic and allergic adverse events among enrollees in...
متن کاملActive Surveillance for Adverse Events: The Experience of the Vaccine Safety Datalink Project abstract
OBJECTIVE: To describe the Vaccine Safety Datalink (VSD) project’s experience with population-based, active surveillance for vaccine safety and draw lessons that may be useful for similar efforts. PATIENTS AND METHODS: The VSD comprises a population of 9.2 million people annually in 8 geographically diverse US health care organizations. Data on vaccinations and diagnoses are updated and extract...
متن کاملPostlicensure surveillance for pre-specified adverse events following the 13-valent pneumococcal conjugate vaccine in children.
Although no increased risk was detected for serious adverse events in the prelicensure trials for the 13-valent pneumococcal vaccine, Prevnar 13(®) (PCV13), continued monitoring of rare but serious adverse events is necessary. A surveillance system using cohort study design was set up to monitor safety of PCV13 immediately after it was included in the childhood immunization program in the Unite...
متن کاملA Comparison of Active Adverse Event Surveillance Systems Worldwide
Post-marketing drug surveillance for adverse drug events (ADEs) has typically relied on spontaneous reporting. Recently, regulatory agencies have turned their attention to more preemptive approaches that use existing data for surveillance. We conducted an environmental scan to identify active surveillance systems worldwide that use existing data for the detection of ADEs. We extracted data abou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pediatrics
دوره 127 Suppl 1 شماره
صفحات -
تاریخ انتشار 2011