Ventricular beat detection in single channel electrocardiograms

نویسندگان

  • Ivan A Dotsinsky
  • Todor V Stoyanov
چکیده

BACKGROUND Detection of QRS complexes and other types of ventricular beats is a basic component of ECG analysis. Many algorithms have been proposed and used because of the waves' shape diversity. Detection in a single channel ECG is important for several applications, such as in defibrillators and specialized monitors. METHODS The developed heuristic algorithm for ventricular beat detection includes two main criteria. The first of them is based on steep edges and sharp peaks evaluation and classifies normal QRS complexes in real time. The second criterion identifies ectopic beats by occurrence of biphasic wave. It is modified to work with a delay of one RR interval in case of long RR intervals. Other algorithm branches classify already detected QRS complexes as ectopic beats if a set of wave parameters is encountered or the ratio of latest two RR intervals RRi-1/RRi is less than 1:2.5. RESULTS The algorithm was tested with the AHA and MIT-BIH databases. A sensitivity of 99.04% and a specificity of 99.62% were obtained in detection of 542014 beats. CONCLUSION The algorithm copes successfully with different complicated cases of single channel ventricular beat detection. It is aimed to simulate to some extent the experience of the cardiologist, rather than to rely on mathematical approaches adopted from the theory of signal analysis. The algorithm is open to improvement, especially in the part concerning the discrimination between normal QRS complexes and ectopic beats.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-beat analysis of ventricular late potentials in the surface electrocardiogram using the spectrotemporal pattern recognition algorithm in patients with coronary artery disease.

AIMS Post-infarction risk stratification can be ascertained from beat-to-beat variations in ventricular late potentials. However, gaining such information by conventional late potential analysis using signal averaging is still not possible. METHODS We therefore developed the spectrotemporal pattern recognition algorithm in order to detect beat-to-beat variations in late potentials. Based on t...

متن کامل

Arrhythmia Diagnosis Using Morphology and Timing from Atrial and Ventricular Leads

Reliable computer arrhythmia diagnosis is mostly restricted to ventricular arrhythmias because information about atrial activation cannot be reliably obtained from surface lead electrocardiograms (ECGs) [1,2,3]. A two channel computer arrhythmia detection system has been designed and successfully tested on a data base of a simultaneous esophageal electrograms and surface lead ECGs. The system h...

متن کامل

Wavelet Entropy as a Measure of Ventricular Beat Suppression from the Electrocardiogram in Atrial Fibrillation

A novel method of quantifying the effectiveness of the suppression of ventricular activity from electrocardiograms (ECGs) in atrial fibrillation is proposed. The temporal distribution of the energy of wavelet coefficients is quantified by wavelet entropy at each ventricular beat. More effective ventricular activity suppression yields increased entropies at scales dominated by the ventricular an...

متن کامل

Real time electrocardiogram QRS detection using combined adaptive threshold

BACKGROUND QRS and ventricular beat detection is a basic procedure for electrocardiogram (ECG) processing and analysis. Large variety of methods have been proposed and used, featuring high percentages of correct detection. Nevertheless, the problem remains open especially with respect to higher detection accuracy in noisy ECGs METHODS A real-time detection method is proposed, based on compari...

متن کامل

The orthogonal electrocardiogram in left ventricular hypertrophy.

It has been shown experimentally that three bipolar electrocardiograms from the main axes of the body contain as much or more information about QRS forces than 12-lead electrocardiograms (Frank et al., 1955; Schmitt and Simonson, 1955; and Newman et al., 1955). A clinical comparison of such a three-lead system and the 12 conventional leads has not yet been reported, and one aim of the present s...

متن کامل