Simultaneous Measurement of Kidney Function by Dynamic Contrast Enhanced MRI and FITC-Sinistrin Clearance in Rats at 3 Tesla: Initial Results

نویسندگان

  • Frank G. Zöllner
  • Daniel Schock-Kusch
  • Sandra Bäcker
  • Sabine Neudecker
  • Norbert Gretz
  • Lothar R. Schad
چکیده

Glomerular filtration rate (GFR) is an essential parameter of kidney function which can be measured by dynamic contrast enhanced magnetic resonance imaging (MRI-GFR) and transcutaneous approaches based on fluorescent tracer molecules (optical-GFR). In an initial study comparing both techniques in separate measurements on the same animal, the correlation of the obtained GFR was poor. The goal of this study was to investigate if a simultaneous measurement was feasible and if thereby, the discrepancies in MRI-GFR and optical-GFR could be reduced. For the experiments healthy and unilateral nephrectomised (UNX) Sprague Dawley (SD) rats were used. The miniaturized fluorescent sensor was fixed on the depilated back of an anesthetized rat. A bolus of 5 mg/100 g b.w. of FITC-sinistrin was intravenously injected. For dynamic contrast enhanced perfusion imaging (DCE-MRI) a 3D time-resolved angiography with stochastic trajectories (TWIST) sequence was used. By means of a one compartment model the excretion half-life (t1/2) of FITC-sinistrin was calculated and converted into GFR. GFR from DCE-MRI was calculated by fitting pixel-wise a two compartment renal filtration model. Mean cortical GFR and GFR by FITC-sinistrin were compared by Bland-Altman plots and pair-wise t-test. Results show that a simultaneous GFR measurement using both techniques is feasible. Mean optical-GFR was 4.34 ± 2.22 ml/min (healthy SD rats) and 2.34 ± 0.90 ml/min (UNX rats) whereas MRI-GFR was 2.10 ± 0.64 ml/min (SD rats) and 1.17 ± 0.38 ml/min (UNX rats). Differences between healthy and UNX rats were significant (p<0.05) and almost equal percentage difference (46.1% and 44.3%) in mean GFR were assessed with both techniques. Overall mean optical-GFR values were approximately twice as high compared to MRI-GFR values. However, compared to a previous study, our results showed a higher agreement. In conclusion, the possibility to use the transcutaneous method in MRI may have a huge impact in improving and validating MRI methods for GFR assessment in animal models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two non-invasive GFR-estimation methods in rat models of polycystic kidney disease: 3.0 Tesla dynamic contrast-enhanced MRI and optical imaging.

BACKGROUND The aim of this study was the assessment of kidney morphology and glomerular filtration rate (GFR) in rat models of polycystic kidney disease and a healthy control group of Sprague-Dawley rats (SD rats). The performance of two non-invasive GFR estimation methods-3.0 Tesla magnetic resonance imaging (MRI) and optical imaging were investigated. Data of GFR assessment was compared to su...

متن کامل

Transcutaneous measurement of glomerular filtration rate using FITC-sinistrin in rats.

BACKGROUND Inulin/sinistrin (I/S) clearance is a gold standard for an accurate assessment of glomerular filtration rate (GFR). Here we describe and validate an approach for a transcutaneous determination of GFR by using fluorescein-isothiocyanate-labelled sinistrin (FITC-S) in rats. METHODS Using a small animal imager, fluorescence is measured over the depilated ear of a rat after the injecti...

متن کامل

Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity

Transcutaneous assessment of fluorescein isothiocyanate (FITC)-sinistrin clearance using a small animal imager has recently been validated as an accurate method for the measurement of glomerular filtration rate (GFR) in freely moving rats. This technique involves a brief, light period of anesthesia during which the imager is adhered to the rat and FITC-sinistrin is administered. The rat is then...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

A Pilot Study to Assess the Feasibility of Transcutaneous Glomerular Filtration Rate Measurement Using Fluorescence-Labelled Sinistrin in Dogs and Cats

In dogs and cats an assessment of renal function is often needed, however, existing methods including urine and plasma clearances are invasive, cumbersome and time consuming. This pilot study evaluated the feasibility of a transcutaneous glomerular filtration rate (GFR) measurement in dogs and cats. Additionally the optimal dose and location for the transcutaneous measurement device were invest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013