Diagnostic performance of an expert system for the interpretation of myocardial perfusion SPECT studies.
نویسندگان
چکیده
UNLABELLED An expert system (PERFEX) developed for the computer-assisted interpretation of myocardial perfusion SPECT studies is now becoming widely available. To date, a systematic validation of the diagnostic performance of this expert system for the interpretation of myocardial perfusion SPECT studies has not been reported. METHODS To validate PERFEX's ability to detect and locate coronary artery disease (CAD), we analyzed 655 stress/rest myocardial perfusion prospective SPECT studies in patients who also underwent coronary angiography. The patient population comprised CAD patients (n = 480) and healthy volunteers (n = 175) (449 men, 206 women). Data from 461 other patient studies were used to implement and refine 253 heuristic rules that best correlated the presence and location of left ventricular myocardial perfusion defects on SPECT studies with angiographically detected CAD and with human expert visual interpretations. Myocardial perfusion defects were automatically identified as segments with counts below sex-matched normal limits. PERFEX uses the certainty of the location, size, shape, and reversibility of the perfusion defects to infer the certainty of the presence and location of CAD. The visual interpretations of tomograms and polar maps, vessel stenosis from coronary angiography, and PERFEX interpretations were all accessed automatically from databases and were used to automatically generate comparisons between diagnostic approaches. RESULTS Using the physician's reading as a gold standard, PERFEX's sensitivity and specificity levels for detection and localization of disease were, respectively, 83% and 73% for CAD, 76% and 66% for the left anterior descending artery, 90% and 70% for the left circumflex artery, and 74% and 79% for the right coronary artery. These results were extracted from a receiver operating characteristic curve using the average optimal input certainty factor. CONCLUSION This study shows that the diagnostic performance of PERFEX for interpreting myocardial perfusion SPECT studies is comparable with that of nuclear medicine experts in detecting and locating CAD.
منابع مشابه
Myocardial perfusion SPECT: Perfusion quantification
Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically. Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...
متن کاملCorrelation of myocardial Tc 99m-MIBI perfusion SPECT with coronary angiography in Namazi Hospital/Shiraz/Iran [Persian]
Coronary heart disease (CAD) is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of CAD and is suggested by many investigators in recent years. In this study, 64 patients wh...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملThe truncation artifact in a skinny patient following myocardial perfusion SPECT
Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...
متن کاملDiffuse bilateral breast uptake on the myocardial perfusion SPECT of a nursing female
Bilateral diffuse intense breast uptake was noted in a 40 year old female who was evaluated with Tc-99m sestamibi (MIBI) myocardial perfusion scan for possible ischemia. She was breast feeding her 1.5 year old child. The intense uptake in the breasts was superimposed on the apical and anteroapical regions of the myocardium and caused interpretation problem. We recom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 42 8 شماره
صفحات -
تاریخ انتشار 2001