A simple manometer for the continuous measurement of intra-ocular pressure.

نویسندگان

  • H DAVSON
  • C PURVIS
چکیده

THE adequate measurement of the intra-ocular pressure, both clinically and experimentally, has remained a baffling problem. The tonometer has obvious disadvantages whiclh have been summarized by Duke-Elder (1932). Chief amongst these, in the opinion of the present authors, is the possibility of self-deception, since the variations in the results of repeated determinations are often quite large and there is always a danger that the investigator will choose unconsciously the value expected. Manometric methods involve the insertion of a needle into the anterior chamber; this of itself may upset the normal phvsiology of the eye, although unequivocal evidence that it does so is lacking. Moreover the investigator is ignorant of the pressure within the eye before inserting the needle, so that to prevent loss or gain of fluid by the eye, he must arbitrarily choose a certain pressure of saline within the needle to minimize these changes An incorrect choice may disturb the normal mechanism of production and drainage of aqueous humour, and there is thus some uncertainty regarding the physiological condition of the eye on this count and greater uncertainty regarding the true value of the intra-ocular pressure in the eye before the needle was inserted, since the pressure imposed on the eye by the saline in the needle may persist for some time. Again, the mechanical registration of changes in the intra-ocular pressure requires that fluids either leave the eye or enter it; this may be largely cut down by a compensatory device in which the excursions of a minute bubble of air inthe recording system are kept to a minimum; the operation of such a compensator is, however, tiresome, and a membrane-type manometer, in which very small changes in the volume of fluid in the sy$tem are magnified into large excursions of a reflected beam of light, is preferable. The instrument'to be described here is of this type and gives a deflection of some 3 to 4 in. of a light spot on a scale, 5 feet away, in response to a rise in pressure of 10 cm. H20; the fluid loss involved in this reflection is only 8 mm. corresponding to some 2 to 3 minutes' production of aqueous humour if present estimates of this rate are acceptable; it is sufficiently sensitive to show the normal pulsation corresponding to the arterial systole.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تاثیر پروپوفول در جلوگیری از افزایش فشار چشم بدنبال تزریق سوکسینیل کولین و لوله گذاری نای

Background and purpose: Penetrating eye injury is one of the most frequent trauma admitted in ophtalmological emergency rooms. The major concern when treating such a trauma is increased intra-ocular pressure and vitreous loss as a side effect of Succinylcholine and endotracheal intubation with no appropriate substitute drug available yet. This study is aimed to determine whether the use of...

متن کامل

Design and Simulation of piezorestive pressure sensor for AFM Probe the displacement measurement

investigating pressure applied in surface vertically that is done by use of mechanical procedures isn’t efficient to measure pressure applied in inner surface of reservoir or pipes having gas due to entering pressure into whole walls and different surfaces. So, in order to measure this kind of pressure, several studies were conducted in past decades and also various procedures were proposed tha...

متن کامل

Observations on the Intra-Ocular Pressure in Cats

mum quantity of ether followed by chloralose 80 milligrammes per kilogramme body-weight being injected intravenously. The eye cannula, combined with the compensatory manometer without the optical arrangement, made on the lines of Sir Stewart Duke-Elder's manometer (1932), was used throughout. The cat was allowed to settle for two hours after the insertion of the cannula into the eye. The variat...

متن کامل

The Lability Test.

Methods The test is a combined one. One hand is put into ice-cold water and at the same time constriction is applied to the neck in order to increase the venous pressure in the head. The latter is done by means of an ordinary sphygmo-manometer with the blood pressure cuff round the neck. We have only used a pressure of 40 mm. Hg. in the cuff. Bloomfield (1947) and Bloomfield and Kelterman (1947...

متن کامل

Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma

Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 1950