Epicardial mapping of ventricular defibrillation with monophasic and biphasic shocks in dogs.

نویسندگان

  • X Zhou
  • J P Daubert
  • P D Wolf
  • W M Smith
  • R E Ideker
چکیده

To study the mechanism of defibrillation and the reason for the increased defibrillation efficacy of biphasic waveforms, the potential gradient in a 32 x 30-mm region of the right ventricle in 15 dogs was progressively lowered in four steps while a strong potential gradient field was maintained throughout the rest of the ventricular myocardium. The volume of right ventricle beneath the plaque was 10 +/- 2% of the total ventricular mass. A 10-msec monophasic (eight dogs) or 5/5-msec biphasic (seven dogs) truncated exponential shock 30% above the defibrillation threshold voltage was given via electrodes on the left ventricular apex and right atrium to create the strong potential gradient field. Simultaneously, a weaker shock with the same waveform but opposite polarity was given via mesh electrodes on either side of the small right ventricular region to cancel part of the potential difference in the region and to create one of the four levels of potential gradient fields. Shock potentials and activations were recorded from 117 epicardial electrodes in the small region, and in one dog global epicardial activations and potentials were recorded from a sock containing 72 electrodes. Each gradient field was tested 10 times for successful defibrillation after 10 seconds of electrically induced fibrillation. For both monophasic and biphasic shocks, the percentage of successful defibrillation attempts decreased (p < 0.05) as the potential gradient decreased in the small region. Defibrillation was successful approximately 80% of the time for a mean +/- SD potential gradient of 5.4 +/- 0.8 V/cm for monophasic shocks and 2.7 +/- 0.3 V/cm for biphasic shocks (p < 0.05). No postshock activation fronts arose from the small region for eight waveform when the gradient was more than 5 V/cm. For both waveforms, the postshock activation fronts after the shocks were markedly different from those just before the shock and exhibited either a focal origin or unidirectional conduction.(ABSTRACT TRUNCATED AT 400 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relation of atrial refractoriness to upper and lower limits of vulnerability for atrial fibrillation/flutter following implantable ventricular defibrillator shocks.

BACKGROUND Implantable ventricular cardioverter defibrillator (ICD) shocks can cause atrial fibrillation/flutter (AF). This study investigated the pathogenesis of AF after ICD shocks in a canine model. METHODS AND RESULTS The study was conducted in 8 dogs. In 5 dogs (group 1), truncated exponential (8 ms, 78% tilt) monophasic and biphasic shocks were delivered through a bipolar epicardial (pa...

متن کامل

Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms.

A reduction in the shock strength required for defibrillation would allow use of a smaller automatic implantable cardioverter-defibrillator and would reduce the possibility of myocardial damage by the shock. Most internal defibrillation electrodes require 5 to 25 J for successful defibrillation in human beings and in dogs. In an attempt to lower the shock strength needed for defibrillation, we ...

متن کامل

Virtual electrode-induced phase singularity: a basic mechanism of defibrillation failure.

Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarizat...

متن کامل

A Basic Mechanism of Defibrillation Failure

Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarizat...

متن کامل

Biphasic shocks compared with monophasic damped sine wave shocks for direct ventricular defibrillation during open heart surgery.

BACKGROUND Biphasic waveform shocks are more effective than monophasic shocks for transchest ventricular defibrillation, atrial cardioversion, and defibrillation with implantable defibrillators but have not been studied for open chest, intraoperative defibrillation. This prospective, blinded, randomized clinical study compares biphasic and monophasic shock effectiveness and establishes intraope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 72 1  شماره 

صفحات  -

تاریخ انتشار 1993