Fingerprinting polychlorinated biphenyls (PCBs) in environmental samples using comprehensive two-dimensional gas chromatography with time-of- flight mass spectrometry

نویسندگان

  • David Megson
  • Robert Kalin
  • Paul J. Worsfold
  • Caroline Gauchotte-Lindsay
  • Maeve C. Lohan
  • Sean Comber
  • Thomas A. Brown
  • Gwen O’Sullivan
چکیده

A GCxGC-TOFMS installed with a Rtx-PCB (60 m x 0.18 mm x 0.18 μm) in the first dimension and Rxi-17 (1.5 m x 0.1 mm x 0.1 μm) column in the second dimension was used to separate 188 out of 209 congeners. A further 12 congeners were identified through additional data processing resulting in the identification of a total of 200 congeners. However, caution is advised if these 12 congeners were to be used in quantitative assessments. The remaining 9 co-eluting congeners were three doublets (CB65 + CB62, CB160 + CB163 and CB201 + CB204) and one triplet (CB20 + CB21 + CB33). This method was tested on five Aroclors and resulted in the separation of all congeners present in the heavier Aroclor mixtures A1254 and A1260. The suitability of this method for applications in biological matrices was demonstrated on extracted whiting and guillemot liver samples which resulted in the identification of 137 individual PCBs in the whiting liver sample and 120 in the guillemot sample. Fingerprinting was able to show clear differences in the PCB signature of the two animals. This highlights the potential of this method for PCB fingerprinting in environmental forensics studies and other assessments that require congener specific analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive two-dimensional gas chromatography time of flight mass spectrometry (GC×GC-TOFMS) for environmental forensic investigations in developing countries.

The disposal and dumping of toxic waste is a matter of growing concern in developing countries, including South Africa. Frequently these countries do not possess access to gas chromatography-high resolution mass spectrometry (GC-HRMS) for the determination of persistent organic pollutants (POPs). This publication describes an alternative approach to the investigation of toxic waste using compre...

متن کامل

Fingerprinting polychlorinated biphenyls in environmental samples using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry.

A GC × GC-TOFMS installed with a Rtx-PCB (60 m × 0.18 mm × 0.18 μm) in the first dimension and Rxi- 17 (1.5 m × 0.1 mm × 0.1 μm) column in the second dimension was used to separate 188 out of 209 congeners. A further 12 congeners were identified through additional data processing resulting in the identification of a total of 200 congeners. However, caution is advised if these 12 congeners were ...

متن کامل

Method development for the analysis of polybrominated diphenyl ethers, polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzo-furans in single extract of sediment samples.

A comprehensive method was developed for quantitative analysis of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples. The sample preparation procedure included two fractionation steps using silver nitrate silica chromatography to separate PBDEs from PCBs and PC...

متن کامل

Recent advances in mass spectrometric measurement of dioxins.

Past years, many efforts have been dedicated to the development of alternative analytical methods for the measurement of dioxins in various types of matrices. Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) are compounds that are present in samples at part-per-billion (ppb) or part-per-trillion (ppt) level. Their measurement...

متن کامل

Polychlorinated biphenyls (PCBs) analysis using a miniaturized high-resolution time-of-flight mass spectrometer "MULTUM-S II".

In this study, we conducted polychlorinated biphenyls (PCBs) analysis using fast gas chromatography (GC)/high-resolution mass spectrometry (HRMS). Mass spectrometry (MS) was performed with a miniature multi-turn time-of-flight (TOF) analyzer called "MULTUM-S II". MULTUM-S II is truly a portable high resolution mass spectrometer. The mass spectrometer's high resolution capability is due to its t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014