Improving the spatial resolution of whole-head magnetic resonance inverse imaging using partition-encoding gradient blips
نویسندگان
چکیده
Using simultaneous acquisition from multiple channels of a radio-frequency (RF) coil array, magnetic resonance inverse imaging (InI) achieves functional MRI acquisitions at a rate of 100 ms per whole-brain volume [1]. InI accelerates the scan by leaving out partition encoding steps and reconstructs images by solving under-determined inverse problems using RF coil sensitivity information. Hence, the correlated spatial information available in the coil array causes spatial blurring in the InI reconstruction. Here, we propose a method that employs gradient blips in the partition encoding direction during the acquisition to provide extra spatial encoding in order to better differentiate signals from different partitions.
منابع مشابه
Improving the spatial resolution of magnetic resonance inverse imaging via the blipped-CAIPI acquisition scheme
Using simultaneous acquisition from multiple channels of a radio-frequency (RF) coil array, magnetic resonance inverse imaging (InI) achieves functional MRI acquisitions at a rate of 100ms per whole-brain volume. InI accelerates the scan by leaving out partition encoding steps and reconstructs images by solving under-determined inverse problems using RF coil sensitivity information. Hence, the ...
متن کاملDynamic magnetic resonance inverse imaging of human brain function.
MRI is widely used for noninvasive hemodynamic-based functional brain imaging. In traditional spatial encoding, however, gradient switching limits the temporal resolution, which makes it difficult to unambiguously identify possible fast nonhemodynamic changes. In this paper we propose a novel reconstruction approach, called dynamic inverse imaging (InI), that is capable of providing millisecond...
متن کاملMulti-projection magnetic resonance inverse imaging of the human visuomotor system
Using highly parallel radiofrequency (RF) detection, magnetic resonance inverse imaging (InI) can achieve 100 ms temporal resolution with whole brain coverage. This is achieved by trading off partition encoding steps and thus spatial resolution for a higher acquisition rate. The reduced spatial information is estimated by solving under-determined inverse problems using RF coil sensitivity infor...
متن کاملImproving high-resolution Q-Ball imaging with a head insert gradient: Bootstrap and SNR analysis
Introduction. The ability to depict small structures of the central nervous system using diffusion-weighted (DW) magnetic resonance imaging (MRI) is notably limited by the spatial resolution and sensitivity of the diffusion-encoded images. However, voxels smaller than ~6 mm (1.8mm isotropic) are difficult to achieve in conventional clinical scanners given the limited signal-to-noise ratio (SNR)...
متن کاملMagnetic Resonance Multi-view Inverse Imaging (MV InI) for Human Brain
Dynamic MRI usually uses echo-planar imaging (EPI) [1] to achieve high temporal resolution. In brain imaging, modern MRI systems can achieve 3D spatial encoding with the whole-brain coverage using multi-slice EPI with TR of 2 s. A significant amount of time of multi-slice EPI is spent over k-space traversal. Recently, we proposed the MR inverse imaging (InI) [2] to achieve the unprecedented tem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013