Dedicated brain PET system of PET/MR for brain research.

نویسندگان

  • Li Cheng
  • Yaqiang Liu
  • Tianyu Ma
  • Shi Wang
  • Qingyang Wei
  • Tianpeng Xu
چکیده

Institute of Medical Physics, Department of Engineering Physics, Tsinghua University, Beijing, China This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

The effect of incorporating the quantitative analysis besides visual assessments of 18F-FDG brain PET images for the localization of epileptogenic zones

Introduction: FDG Brain PET is a valuable paraclinical tool for presurgical assessments of patients suffering from refractory epilepsy. By the widespread accessibility of PET, recognizing the functional lesions has become a current practical method especially in preoperative evaluations of the partial epilepsy disorders. The aim of our study was to assess the impact of quantit...

متن کامل

Impact of MR-safe headphones on PET attenuation in combined PET/MRI scans

BACKGROUND MR headphones are attenuation sources affecting PET quantification in hybrid PET/MRI. Despite potentially better patient communication, usage in PET/MRI scans is not approved by the vendor. This study aims to determine the impact of headphones on PET by means of phantom and patient scans. Additionally, the perceived benefit of using headphones was evaluated. FINDINGS A cylinder pha...

متن کامل

18F-FDG PET/CT findings in a possible MELAS syndrome: A case study

Mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS) syndrome is a rare congenital disorder of mitochondrial DNA, presenting a wide range of clinical symptoms comprising headaches, seizures, aphasia, hearing loss, visual defects, and hemiparesis. Herein we report a case of a previously asymptomatic 40-year-old male who presented with recurrent headache, seiz...

متن کامل

Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging

Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • EJNMMI physics

دوره 2 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015