Using MRI of the optic nerve sheath to detect elevated intracranial pressure

نویسندگان

  • Heidi Harbison Kimberly
  • Vicki E Noble
چکیده

The current gold standard for the diagnosis of elevated intracranial pressure (ICP) remains invasive monitoring. Given that invasive monitoring is not always available or clinically feasible, there is growing interest in non-invasive methods of assessing ICP using diagnostic modalities such as ultrasound or magnetic resonance imaging (MRI). Increased ICP is transmitted through the cerebrospinal fluid surrounding the optic nerve, causing distention of the optic nerve sheath diameter (ONSD). In this issue of Critical Care, Geeraerts and colleagues describe a non-invasive method of diagnosing elevated ICP using MRI to measure the ONSD. They report a positive correlation between measurements of the ONSD on MRI and invasive ICP measurements. If the findings of this study can be replicated in larger populations, this technique may be a useful non-invasive screening test for elevated ICP in select populations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Brain Trauma Measurement of Optic Nerve Sheath Diameter for the Assessment of Risk of Raised Intracranial Pressure

Raised intracranial pressure (ICP) is associated with poor outcome after brain injury, but is difficult to detect without invasive devices. As a part of the central nervous system, the optic nerve is surrounded by a dural sheath, and the subarachnoid space surrounding the optic nerve is subject to the same pressure changes as the intracranial compartment. Distension of the optic nerve sheath re...

متن کامل

Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure

INTRODUCTION The dural sheath surrounding the optic nerve communicates with the subarachnoid space, and distends when intracranial pressure is elevated. Magnetic resonance imaging (MRI) is often performed in patients at risk for raised intracranial pressure (ICP) and can be used to measure precisely the diameter of optic nerve and its sheath. The objective of this study was to assess the relati...

متن کامل

A rapid noninvasive method of detecting elevated intracranial pressure using bedside ocular ultrasound: application to 3 cases of head trauma in the pediatric emergency department.

Managing pediatric head trauma with elevated intracranial pressure in the acute setting can be challenging. Bedside ocular ultrasound for measuring optic nerve sheath diameters has been recently proposed as a portable noninvasive method to rapidly detect increased intracranial pressure in emergency department patients with head trauma. Prior study data agree that the upper limit of normal optic...

متن کامل

Optic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure

A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2008