Pressure drop across artificially induced stenoses in the femoral arteries of dogs.

نویسندگان

  • D F Young
  • N R Cholvin
  • A C Roth
چکیده

Stenoses were artificially induced in 13 large mongrel dogs by implanting small hollow cylindrical plugs in their femoral arteries. The instantaneous pressure drop across the stenosis and the flow rate were measured for a series of stenoses varying in severity from 52.3 to 92.2%. Mean pressure drops ranged from approximately 2 to 30 mm Hg with peak pressure drops ranging from 9 to 53 mm Hg. The pressure drop could be estimated from a relatively simple equation that was originally developed for flow through model stenoses. With this equation, the effects of several factors that contribute to the pressure drop, including stenosis size and shape, artery lumen diameter, blood density, blood viscosity, and velocity and acceleration of flow, could be clearly delineated. For severe stenoses, unsteady flow effects were small and flow could be treated as quasi-steady. Calculations based on data obtained from the dog experiments revealed that the mean pressure drop across a stenosis increased nonlinearly with percent stenosis and showed quantitatively that the value of critical stenosis decreased with increasing demand for blood flow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamics of arterial stenoses at elevated flow rates.

This study is concerned with the pressure drop that develops across an arterial stenosis, with particular emphasis on the effect of the stenosis at high blood flow rates induced by a locally administered vasodilator drug. Stenoses, ranging in severity from 55.7% to 91.0% reduction in lumen area were artificially induced in the femoral and carotid arteries of large mongrel dogs. Instantaneous fl...

متن کامل

Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs

Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...

متن کامل

Pressure-derived measurement of coronary flow reserve.

OBJECTIVES We aimed to validate the technique of measuring the coronary flow reserve (CFR) with coronary pressure measurements against an established thermodilution technique. BACKGROUND The CFR has traditionally required measurement of coronary blood flow velocity with the Doppler wire and, more recently, using a thermodilution technique with the coronary pressure wire. However, recent work ...

متن کامل

The effect of turbulence model on predicting the development and progression of coronary artery atherosclerosis

A severe case of stenosis in coronary arteries results in turbulence in the blood flow which may lead to the formation or progression of atherosclerosis. This study investigated the turbulent blood flow in a coronary artery with rigid walls, as well as 80% single and double stenoses on blood flow. A finite element-based software package, ADINA 8.8, was employed to model the blood flow. The hemo...

متن کامل

Fluid dynamics of coronary artery stenosis.

A large-scale model of the coronary circulation, instrumented to permit detailed pressure and velocity measurements, has been used to study flow through isolated stenotic elements in large coronary arteries. Pulsatile aortic and instantaneous peripheral resistance were stimulated with servovalves. A variety of axisymmetric and asymmetric stenoses were studied and flow separation was found to oc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 1975