Effect of component design in retrieved bipolar hip hemiarthroplasty systems.
نویسندگان
چکیده
Primary articulation of bipolar hemiarthroplasty systems is at the femoral head-liner interface. The purpose of this study was to compare observed damage modes on 36 retrieved bipolar systems with implant, demographic, intraoperative, and radiographic data to elucidate the effects of component design, specifically locking mechanism, on clinical performance. Retrieved bipolar hip hemiarthroplasty systems of 3 different design types were obtained, disassembled, and evaluated macro- and microscopically for varying modes of wear, including abrasion, burnishing, embedding, scratching, and pitting. Clinical record review and radiographic analysis were performed by a senior orthopedic surgery resident. Average bipolar hip hemiarthroplasty system term of service was 46 months (range, 0.27-187 months). All devices contained wear debris captured within the articulating space between the femoral head and liner. In 31% of patients without infection, lucency was observed on immediate prerevision radiographs. The system with a leaf locking mechanism showed significantly increased radiographically observed osteolysis (P=.03) compared with a system with a stopper ring locking mechanism. In addition, implant design and observed damage modes, including pitting and third-body particle embedding, were significantly associated with radiographically observed osteolysis.
منابع مشابه
Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...
متن کاملDissociation of a Bipolar Prosthesis after Right Hip Hemiarthroplasty
We report the case of an 84-year-old woman with a dissociated bipolar component of her right hip hemiarthroplasty. Dissociation of components is a rare but increasingly recognized consequence of modular componentry. Radiologists should be aware of the distinction between dislocation of a prosthesis and dissociation of its bipolar components, and be able to describe these complications accuratel...
متن کاملThe Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures
PURPOSE The purpose of this study was to compare the outcomes of osteosynthesis using compression hip screw fixation versus bipolar hemiarthroplasty in AO type A2 intertrochanteric fractures. MATERIALS AND METHODS From March 2003 to December 2009, 89 patients were included in this study. They were treated using compression hip screws (43 cases) or bipolar hemiarthroplasty (46 cases). The mean...
متن کاملComparative study in surgical outcome of intracapsular fracture neck of femur in active elderly patients treated with hemiarthroplasty with Austin Moore's and bipolar prosthesis.
Fracture neck of femur is most commonly encountered fractures in elderly population. Hemiarthroplasty is generally considered to be the treatment of choice in most active elderly patients. However, there is inadequate evidence to support the choice between unipolar or bipolar prosthesis. This study was conducted to analyze the outcome regarding pain, hip function, complication and acetabular er...
متن کاملTreatment of Femoral Neck Fractures: Unipolar Versus Bipolar Hemiarthroplasty
BACKGROUND AND OBJECTIVE Intracapsular femoral neck fractures are common in the elderly population. To avoid the poor outcome of internal fixation and for early mobilization, hemiarthroplasty is performed. However, there is inadequate evidence to support the choice between unipolar or bipolar hemiarthroplasty. The aim of this study was to compare the outcome of unipolar with the bipolar prosthe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 36 9 شماره
صفحات -
تاریخ انتشار 2013