A robust, dynamic R∗ 2-and-field-map-corrected image reconstruction for single shot self-refocusing trajectories at 3T

نویسندگان

  • Sangwoo Lee
  • Jeffrey A. Fessler
  • Douglas C. Noll
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distortion reduction for spiral-fMRI: Comparison of iterative and non-iterative parallel imaging reconstruction algorithms

Introduction Single-shot spiral imaging is a very efficient technique to acquire dynamic data for fMRI experiments rapidly and has profound advantages over single-shot EPI as it distributes the burden over two gradient axes. Similar to EPI, spirals suffer from geometric image distortions, T2*-related blurring, and signal dropout/pile-up artifacts. Parallel imaging (PI) has shown great utility t...

متن کامل

Dynamic field map estimation using a spiral-in/spiral-out acquisition.

The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause geometric distortions in the images when Cartesian k-space trajectories are used...

متن کامل

Field-Corrected Imaging using Joint Estimation of Image and Field Map

1 Abstract In order to reduce acquisition time in dynamic scans, while still correcting for field inhomogeneities, an image reconstruction method is introduced that simultaneously estimates field-corrected images and their associated field maps while acquiring only part of k-space at each readout. A two-shot variable density spiral sequence is combined with a regularized nonlinear least-squares...

متن کامل

A modified EPI sequence for high-resolution imaging at ultra-short echo time.

A robust modification of echo-planar imaging dubbed double-shot echo-planar imaging with center-out trajectories and intrinsic navigation (DEPICTING) is proposed, which permits imaging at ultra-short echo time. The k-space data is sampled by two center-out trajectories with a minimal delay achieving a temporal efficiency similar to conventional single-shot echo-planar imaging. Intersegment phas...

متن کامل

Efficient Off-resonance Corrected Reconstruction of Rosette Trajectories by Deformed Interpolation Kernels

INTRODUCTION: With the use of multiple localized, small receive coil arrays, single shot whole brain coverage becomes feasible for fMRI applications. Using a 3D rosette trajectory and iterative, regularized reconstruction a 643 volume can be acquired in less than 30ms with acceptable broadening of the point spread function (1). Single shot trajectories suffer from off-resonance effects because ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006