Comparison of metal artifact in digital tomosynthesis and computed tomography for evaluation of phantoms

نویسنده

  • Tsutomu Gomi
چکیده

We compared metal artifact in X-ray digital tomosynthesis (DT) and modern computed tomography (CT) reconstruction to improve the image quality. We compared the images of a prosthetic phantom (titanium) and a contrast-detail phantom obtained by DT using conventional filtered backprojection (FBP), metal artifact reduction (MAR) processing, and simultaneous iterative reconstruction technique (SIRT) methods and those obtained by CT using conventional FBP and adaptive statistical iterative reconstruction methods. The effectiveness of each method for enhancing the visibility of a prosthetic phantom was quantified in terms of the intensity profile and root mean square error, and the removal of ghosting artifacts was quantified in terms of the artifact spread function (ASF). In addition, low contrast resolution was evaluated in terms of the contrast-tonoise ratio. Image error was smaller in the MAR DT images in the near in-focus-plane, and the intensity profiles revealed the beam hardening effect. Streak artifacts were reduced in the SIRT DT and adaptive statistical iterative reconstruction CT images. The ASF performances of the algorithms were ranked in descending order: 1) MAR DT; 2) CT (adaptive statistical iterative reconstruction, and conventional FBP); 3) SIRT DT; and 4) conventional FBP DT. The low contrast resolution was higher in the CT images than in the DT images. In conclusion, a review of the results revealed that the metal artifact reduction was highest for tomosynthesis with MAR processing, and the low contrast resolution performance was highest for CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study

Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013