Myocardial perfusion and MR angiography of chest with SH U 555 C: results of placebo-controlled clinical phase i study.
نویسندگان
چکیده
PURPOSE To evaluate SH U 555 C for contrast material-enhanced three-dimensional magnetic resonance (MR) angiography of the chest and myocardial perfusion. MATERIALS AND METHODS For chest MR angiography, SH U 555 C was intravenously injected at four doses (5, 10, 20, and 40 micromol iron [Fe] per kilogram of body weight) into three healthy volunteers per dose group, and placebo (saline) was injected into one additional volunteer per dose group (16 subjects). With a body phased-array coil, serial high-spatial-resolution breath-hold three-dimensional MR angiography of the chest was performed at baseline, first pass, and 6, 12, 18, 24, 30, 36, and 42 minutes after injection. SH U 555 C (40 micromol Fe/kg) was injected into four additional volunteers to evaluate cardiac perfusion. Signal intensity (SI) was measured in vessels, cardiac chambers, and myocardium to calculate relative SI changes during time. Analysis of variance for multiple comparisons was applied for statistical analysis. Two readers assessed image quality. Subjects were monitored for side effects (cardiovascular reactions) for 24 hours. RESULTS SH U 555 C showed a dose-dependent increase in SI enhancement during first pass and equilibrium phase. SH U 555 C showed dose-dependent increase (range, 259% +/- 160 [SD] at 5 micromol Fe/kg to 907% +/- 370 at 40 micromol Fe/kg) for thoracic aorta during first pass. Intravascular SI did not significantly decrease with time during equilibrium phase within arterial and venous vessels. Image quality remained stable and was diagnostic for highest dose group to 30 minutes, with good to excellent contrast even in smaller blood vessels. For cardiac perfusion, SH U 555 C showed peak enhancement during first pass through right and left ventricles, as well as stable SI during equilibrium phase within cardiac chambers and myocardium. Peak enhancement during first pass was limited due to susceptibility effects, which were more pronounced in right ventricle than in left. Contrast agent was well tolerated, and no cardiovascular reactions occurred. CONCLUSION SH U 555 C bolus injected at highest dose of 40 micromol Fe/kg has capability for depiction at first-pass MR angiography and for cardiac perfusion.
منابع مشابه
Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملRelationship between the location of the most severe myocardial perfusion defects, the most severe coronary artery stenosis and the site of subsequent myocardial infarction [Persian]
This study evaluated the relationship between the location of the most severe coronary artery stenosis and the subsequent acute myocardial infarction (AMI). Methods: Of 1590 patients who were admitted with a diagnosis of AMI, we identified 44 patients who had undergone previous myocardial perfusion SPECT. Thirty-one of these patients also had previous coronary angiography. The relationshi...
متن کاملCorrelation of myocardial Tc 99m-MIBI perfusion SPECT with coronary angiography in Namazi Hospital/Shiraz/Iran [Persian]
Coronary heart disease (CAD) is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of CAD and is suggested by many investigators in recent years. In this study, 64 patients wh...
متن کاملComparative study of myocardial perfusion SPECT and coronary angiography [Persian]
Abstract is NOT available
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiology
دوره 231 2 شماره
صفحات -
تاریخ انتشار 2004