Reduced corneal thickness and enlarged anterior chamber in a novel ColVIIIa2G257D mutant mouse.

نویسندگان

  • Oliver Puk
  • Claudia Dalke
  • Julia Calzada-Wack
  • Nafees Ahmad
  • Matthias Klaften
  • Sibylle Wagner
  • Martin Hrabé de Angelis
  • Jochen Graw
چکیده

PURPOSE The purpose of this study was the morphologic and genetic characterization of the novel eye size mutant Aca23 in the mouse. METHODS The eyes of the mutants were characterized in vivo by optical low-coherence interferometry, Scheimpflug imaging, and funduscopy. Visual acuity was examined using a virtual optomotor system. Morphology was studied by histology, in situ hybridization, and immunohistochemistry. Linkage analysis was performed using genomewide scans with single nucleotide polymorphisms and microsatellite markers. RESULTS Aca23 is a new semidominant eye size mutant that was discovered in an ENU mutagenesis screen. The phenotype includes increased anterior chamber depths, extended axial lengths, and reduced thickness of corneal layers. Aca23 was mapped to chromosome 4. A G-->A point mutation was identified at cDNA position 770 of Col8a2 encoding collagen VIII alpha2. The transition results in a G257D amino acid exchange affecting a highly conserved glycine residue in the collagenous domain. Proliferation of corneal endothelium, eye fundus, and visual acuity are not affected. CONCLUSIONS The mouse mutant Aca23 described here offers the first point mutation of the Col8a2 gene in the mouse. The results of this study suggest that a functional collagen VIII alpha2 is essential for the correct assembly of the Descemet's membrane and for corneal stability. Aca23 might be used as a novel model for keratoglobus.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

Biometric measurement of the mouse eye using optical coherence tomography with focal plane advancement

PURPOSE To demonstrate that high-resolution biometry is possible in mouse eyes in vivo, using real-time OCT with focal plane advancement by a stepper motor. METHODS OCT images of eyes were taken from nine 29-day-old C57BL/6 mice(18 eyes) on two consecutive days. A custom-built real-time OCT instrument with a stepper motor was used to advance the focal plane from the corneal apex to the retina...

متن کامل

Ocular biometry and central corneal thickness in children: a hospital-based study.

PURPOSE To investigate the distribution of axial length, anterior chamber depth, lens thickness, vitreous chamber depth, and central corneal thickness in children at different age groups. METHODS We studied 364 eyes in 182 children with ages between 1 and 12 years. Axial length, anterior chamber depth, lens thickness, and vitreous chamber depth were measured by ultrasound biometry. Central co...

متن کامل

Refractive correction method for digital charge-coupled device-recorded Scheimpflug photographs by means of ray tracing.

Our purpose is to correct digital CCD-recorded Scheimpflug photographs, imaging both the anterior and posterior corneal surface, the anterior chamber, and the anterior eye lens surface for optical distortions. In a ray-tracing algorithm the imaging of the posterior corneal surface in a given Scheimpflug photograph is corrected by applying Snell's law on parallel incident rays entering through t...

متن کامل

Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device

PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2009