Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia.
منابع مشابه
Interference Studies Using Multidimensional Mapping of Cross-reactive Sensors: Applications in Blood Monitoring of Clozapine
Title of Document: INTERFERENCE STUDIES USING MULTIDIMENSIONAL MAPPING OF CROSS-REACTIVE SENSORS: APPLICATIONS IN BLOOD MONITORING OF CLOZAPINE Sheryl E. Chocron, Master of Science, 2014 Directed By: Reza Ghodssi, Herbert Rabin Distinguished Chair of Engineering, Electrical and Computer Engineering Point-of-care sensors are used in clinical applications for diagnosing and monitoring health cond...
متن کاملAn Electrochemical Micro-System for Clozapine Antipsychotic Treatment Monitoring
Clozapine is the most effective antipsychotic medication for schizophrenia, but it is underutilized because of the inability to effectively monitor its treatment efficacy and side effects. In this work, we demonstrate the first analytical micro-system for real-time monitoring of clozapine serum levels. An electrochemical lab-on-a-chip is developed and integrated with a catechol-chitosan redox c...
متن کاملProgrammable Semismart Sensor: Relevance to Monitoring Antipsychotics
Mental health disorders are complex and poorly understood but would benefi t from real-time chemical analysis capable of assessing a patient’s current status, personalizing a therapeutic action, and monitoring compliance. Here, an electrochemical sensor is reported for detecting the antipsychotic drug clozapine which is one of the most effective but under-utilized drugs for managing schizophren...
متن کاملThe Binding Effect of Proteins on Medications and Its Impact on Electrochemical Sensing: Antipsychotic Clozapine as a Case Study
Clozapine (CLZ), a dibenzodiazepine, is demonstrated as the optimal antipsychotic for patients suffering from treatment-resistant schizophrenia. Like many other drugs, understanding the concentration of CLZ in a patient's blood is critical for managing the patients' symptoms, side effects, and overall treatment efficacy. To that end, various electrochemical techniques have been adapted due to t...
متن کاملElectrochemical study of the catechol-modified chitosan system for clozapine treatment monitoring.
This work presents a thorough electrochemical and reliability analysis of a sensing scheme for the antipsychotic clozapine. We have previously demonstrated a novel detection approach for this redox-active drug, highly effective in schizophrenia treatment, based on a catechol-modified chitosan film. The biomaterial film enables amplification of the oxidative current generated by clozapine throug...