Design and Cooling Performances of an Air Conditioning System with Two Parallel Refrigeration Cycles for a Special Purpose Vehicle

نویسندگان

  • Moo-Yeon Lee
  • Takahiko Miyazaki
چکیده

The objective of this study is to design and briefly investigate the cooling performances of an air conditioning system for a special purpose vehicle under various experimental conditions. An air conditioning system with two parallel refrigeration cycles consisting of two compressors and two condensers for satisfying the required cooling performance of the special purpose vehicle was tested under extremely hot weather conditions and high thermal load conditions and then optimized by varying the refrigerant charge amount. The optimum refrigerant charge amount of the tested air conditioning system was 1200 g with the consideration of the cooling speed and cooling capacity. The indoor temperatures of the suggested air conditioning system at the refrigerant charge amounts of 1200 g, 1400 g, and 1600 g were 24.7 ◦C, 25.2 ◦C, and 26.4 ◦C, respectively, at the elapsed time of 300 s. The cooling time required to reach a 15.0 ◦C inner temperature in the suggested air conditioning system increased by 13.3% with the decrease of the refrigerant charge amount from 1600 g to 1200 g. The cooling capacity and the coefficient of performance (COP) of the suggested air conditioning system increased by 37.9% and 10.9%, respectively, due to a decrease of the refrigerant charge amount from 1600 g to 1200 g. The observed cooling performance characteristics of the air conditioning system with two parallel refrigeration cycles means it could be suitable for cabin cooling of special purpose vehicles. In addition, the designed special air conditioning system with two parallel refrigeration cycles for a special purpose vehicle was built to ensure a sufficient cooling performance for equipped passengers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Energy-Smart Calculation of Thermal Loads in Mobile and Stationary Heating, Ventilation, Air Conditioning, and Refrigeration Systems

The energy consumption by heating, ventilation, air conditioning, and refrigeration systems forms a large portion of the total energy usage in buildings. Vehicle fuel consumption and emissions are also significantly affected by air conditioning. Air conditioning is also a critical system for hybrid electric vehicles and electric vehicles as the second most energy consuming system after the elec...

متن کامل

Performance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger

In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...

متن کامل

Design and Thermodynamic analysis of solar air humidifier

In this paper, the cooling system of the air humidifire, completely powered by solar energy, has been designed and optimized. In the cooling system, instead of conventional compression cooling systems, the ammonia absorption refrigeration system has been used.Its design is done in a way that the performanceof the system has increased remarkably in environments with high temperature. The ammonia...

متن کامل

Window Air Conditioner with Orthodox Refrigerants

The system design of window air conditioner does not evolve in one day. Due to the continous efforts are taken by the refrigeration and air conditionging professionals, successful and economic models of window air conditioners are currently used. This paper states about the development of window air conditioner with phase change material and water as refrigerants. Developed air conditioner was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017