Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling.

نویسندگان

  • Håkan Hedtjärn
  • Gudrun Alm Carlsson
  • Jeffrey F Williamson
چکیده

Current brachytherapy dose calculations ignore applicator attenuation and tissue heterogeneities, assuming isolated sources embedded in unbounded medium. Conventional Monte Carlo (MC) dose calculations, while accurate, are too slow for practical treatment planning. This study evaluates the efficacy of correlated sampling in reducing the variance of MC photon transport simulation in typical brachytherapy geometries. Photon histories were constructed in the homogeneous geometry and weight correction factors applied to account for the perturbing effect of heterogeneities. Two different estimators, expected value track-length (ETL) and analogue (ANL), were used. The method was tested for disc-shaped heterogeneities and point-isotropic sources as well as for a model 6702 125I seed. Uncorrelated ETL estimation was 10-100 times more efficient than its ANL counterpart. Correlated ETL estimation offered efficiency gains as large as 10(4) in regions where dose perturbations are small (<5%). For perturbations of 40-50%, efficiency gains were in some cases even less than unity. However, correlated ETL was capable of producing less than 2% (I standard deviation) uncertainty in more than 90% of the voxels in 1 CPU hour. Correlated sampling significantly improves efficiency under selected circumstances and, in combination with other variance reduction strategies, may make MC-based treatment planning a reality for brachytherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations

Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

BrachyGUI: an adjunct to an accelerated Monte Carlo photon transport code for patient-specific brachytherapy dose calculations and analysis

A number of accelerated Monte Carlo (MC) codes have been developed in recent years for brachytherapy applications, one of which is PTRAN_CT. Developed as an extension to the well-benchmarked PTRAN code, PTRAN_CT can be used to perform efficient patientspecific dose calculations. The code can explicitly account for the patient geometry converted from computed-tomography (CT) images, as well as p...

متن کامل

Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2002