Design and Control of Single Phase Dynamic Voltage Restorer

نویسندگان

  • Amit Meena
  • Shirazul Islam
  • Sandeep Anand
  • Yogesh Sonawane
  • Sanjay Tungare
چکیده

Dynamic Voltage Restorer (DVR) is a custom power device used in electrical distribution system for power quality improvement. The main application of DVR is for voltage compensation of sensitive loads against voltage disturbances such as voltage sag and voltage swell in distribution lines. It is a series connected device and is able to compensate voltage sag and voltage swell by injecting a voltage with the help of series transformer. The injection of an appropriate voltage component in the event of a voltage disturbance requires a certain amount of real and reactive power. Conventionally, DVR consists of an energy storage device which supplies the required power over the limited duration of the sags. Large magnitude and long duration of sags, lead to heavy financial investment in energy storage unit. To overcome this limitation, a single phase back-toback converter based DVR is implemented in this paper, which eliminates energy storage requirement. In the event of voltage sag, front-end converter acts as active rectifer and other converter acts as inverter, injecting the voltage in series with grid voltage. Real power flows from rectifer to inverter. In case of voltage swell condition, the operation of two converters interchanged and energy is fed back to the shunt converter from the series converter. The effectiveness of control schemes, protection schemes and plug and play operation of DVR is verified through detailed simulation studies. The viability of above schemes is confirmed by the experimental results generated from laboratory prototype developed. Keywords—Dynamic Voltage Restorer, In-phase compensation, Voltage Sag, Voltage Swell.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized Fuzzy Controller Design in Unbalanced Voltage Drop Mode for Dynamic Voltage Restorer

The loss of balanced voltages involves a voltage drop due to symmetric three-phase errors, or the initiation of high-power three-phase loads or symmetric three-phase switches. While these events in an unbalanced way lead to asymmetric voltage drops. Voltage drops can cause asymmetric load on the power grid, the occurrence of volatility, and even network power outage. One of the most common ways...

متن کامل

A New Topology for Interline Dynamic Voltage Restorer Based on Direct Three-Phase Converter

In this paper, a new topology for Interline Dynamic Voltage Restorer (IDVR) is proposed. This topology contains two direct three-phase converters which have been connected together by a common fictitious dc-link. According to the kind of the disturbances, both of the converters can be employed as a rectifier or inverter. The converters receive the required compensation energy from the gird thro...

متن کامل

Voltage profile improvement through online dynamic voltage restorer controlled by chaos-based genetic algorithm

Improving reliability indices, increasing the grid production capacity, reducing power loss during peak periods and fuel cost, and economic and environmental considerations on the one hand, and the progresses made in the field of semiconductor devices on the other hand, are some of the factors that increase the penetration of the renewable energy sources to the distributed network. When the pho...

متن کامل

The Effectiveness of Dynamic Voltage Restorer with the Distribution Networks for Voltage Sag Compensation

This paper discusses the Dynamic voltage restorer (DVR) operation and control for Voltage sags compensation. DVR is a series connected power electronic based device that can quickly mitigate the voltage sags in the system and restore the load voltage to the pre-fault value. Voltage sag associated with faults in transmission and distribution systems, energizing of transformers, and starting of l...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل