To What Extent Are Spatiotemporal and Handrim Kinetic Parameters Comparable between Overground and Wheelchair Simulator Propulsions among Long-term Manual Wheelchair Users?

نویسندگان

  • Mathieu Lalumiere
  • Martine Blouin
  • Felix Chenier
  • Rachid Aissaoui
  • Dany H. Gagnon
چکیده

A repeated cross-sectional research design was used in this study to compare propulsion biomechanics on a newly developed wheelchair simulator to overground natural propulsion. Seventeen individuals (15 men and 2 women) with spinal cord injury between T4 and T12 completed two 20-meter propulsion trials on a tiled surface and two 1-minute propulsion sessions on the simulator. The main outcome measures were perceived exertion, spatio-temporal and pushrim kinetic propulsion parameters. In conclusion, the propulsion biomechanic patterns on the simulator are comparable to overground propulsion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of an Instrumented Handrim to Measure the Kinetic and Kinematic Information by the Hand of User for 3D Analysis of Manual Wheelchair Propulsion Dynamics

The repetitious nature of propelling a wheelchair has been associated with the high incidence of injury among manual wheelchair users (MWUs), mainly in the shoulder, elbow and wrist. Recent literature has found a link between handrim biomechanics and risk of injury to the upper extremity. The valid measurement of three-dimensional net joint forces and torques, however, can lead to a better unde...

متن کامل

Comparison between overground and dynamometer manual wheelchair propulsion.

Laboratory-based simulators afford many advantages for studying physiology and biomechanics; however, they may not perfectly mimic wheelchair propulsion over natural surfaces. The goal of this study was to compare kinetic and temporal parameters between propulsion overground on a tile surface and on a dynamometer. Twenty-four experienced manual wheelchair users propelled at a self-selected spee...

متن کامل

Relationship between shoulder pain and kinetic and temporal-spatial variability in wheelchair users.

OBJECTIVE To examine intra-individual variability of kinetic and temporal-spatial parameters of wheelchair propulsion as a function of shoulder pain in manual wheelchair users (MWUs). DESIGN Cohort. SETTING University research laboratory. PARTICIPANTS Adults with physical disabilities (N=26) who use a manual wheelchair for mobility full time (>80% ambulation). INTERVENTIONS Participants...

متن کامل

Investigation of the performance of an ergonomic handrim as a pain-relieving intervention for manual wheelchair users.

Manual wheelchair users commonly experience pain in their hands and wrists associated with the repetitive stress of propulsion. The objective of this research was to examine the effect of an ergonomic wheelchair handrim as an intervention designed to reduce pain in the hands and wrists and improve functional outcomes for manual wheelchair users. Three studies were conducted to achieve this obje...

متن کامل

Comprehensive Needs Assessment Study and Deployment of QFD Targeted at New Wheelchair Design

Objectives: Extensive use of wheelchair increases caregiver dependency, risk of bedsores, risk of injury during transfer, and so on, and it effectively decreases quality of life, safety, and comfort of the people with disability. Therefore, improving the design of wheelchairs is highly essential in promoting the quality of life and level of participation among people with disability. The design...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014