Validation of a Cannabinoid Quantitation Method Using an Agilent 6430 LC/MS/MS Authors

نویسنده

  • Jason Hudson
چکیده

A method was developed and validated for the quantitation of cannabinoids with LC/MS/MS using an Agilent 6430 Triple Quadrupole LC/MS system. Validation showed that the LC/MS/MS method provides reliable results for the quantitation of THC, OH-THC, and carboxy-THC that meet predetermined acceptance criteria [1]. The concentration range of target compounds used in this validation was chosen to fit the commonly encountered range of analyte concentrations seen in casework. The method displays excellent accuracy and precision for the detection of cannabinoids in blood. Other aspects evaluated during validation include interference, stability, dilution integrity, suppression/enhancement, and recovery for all target compounds.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Analysis of Vitamin D in Serum Using Triple Quadrupole LC/MS

A rapid method for the quantification of 25-OH D2 and 25-OH D3 in serum was developed using the Agilent 1200 Series Rapid Resolution LC (RRLC) system coupled with an Agilent 6430 Triple Quadrupole LC/MS with multimode ionization (MMI). Solid phase extraction minimizes matrix interferences and ion suppression, while enabling automation. Excellent linearity of quantification (R2 > 0.99) was obtai...

متن کامل

A Generic UHPLC/UV/MS Method for Cleaning Verifi cation of Highly Potent Drugs

Cleaning validation (CV) is a Good Manufacturing Practices (GMP) requirement in manufacturing of drug substances and drug products. Liquid Chromatography with UV detection is a common choice for cleaning verifi cation studies for most drugs at sensitivity levels of approximately 20–50 ng/mL. For highly potent drugs, CV methods to reach sensitivity levels of low ng/mL can be implemented using UV...

متن کامل

Quantitation of Oxidation Sites on a Monoclonal Antibody Using an Agilent 1260 Infinity HPLC-Chip/MS System Coupled to an Accurate-Mass

The identification of oxidation sites on a monoclonal antibody (mAb) using an Agilent 1260 Infinity HPLC-Chip/MS system coupled to an Agilent Accurate-Mass 6520 Quadrupole Time-of-Flight (Q-TOF) LC/MS is described. A monoclonal antibody was oxidized by treatment with various concentrations of t-butyl hydroperoxide (t-BHP) to stimulate potential oxidative modifications that may occur during a ma...

متن کامل

Screening and Verifying Mycotoxins in Food with Q-TOF LC/MS and an Accurate Mass Library Authors

This application note describes the creation of an accurate mass library for mycotoxins and related metabolites and its application for the screening of mycotoxins in food. An Agilent 1290 Infinity LC coupled to an Agilent 6550 iFunnel Q-TOF LC/MS was operated in positive and negative electrospray with dual-spray Agilent Jet Stream Technology. Accurate mass spectra were acquired for a large col...

متن کامل

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals Authors

A method using QuEChERS sample preparation and an Agilent 6490 Triple Quadrupole LC/MS has been developed that provides rapid and sub-parts per billion (ppb) detection of synthetic yohimbine and yohimbe bark extract in dietary supplements. Using the chromatographic separation of the diastereomers of yohimbine, the synthetic compound can be distinguished from the tree bark extract. An Agilent 65...

متن کامل