Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas

نویسندگان

  • John Z Chen
  • Ira M Katz
  • Marine Pichelin
  • Kaixian Zhu
  • Georges Caillibotte
  • Michelle L Noga
  • Warren H Finlay
  • Andrew R Martin
چکیده

BACKGROUND Portable oxygen concentrators (POCs) typically include pulse flow (PF) modes to conserve oxygen. The primary aims of this study were to develop a predictive in vitro model for inhaled oxygen delivery using a set of realistic airway replicas, and to compare PF for a commercial POC with steady flow (SF) from a compressed oxygen cylinder. METHODS Experiments were carried out using a stationary compressed oxygen cylinder, a POC, and 15 adult nasal airway replicas based on airway geometries derived from medical images. Oxygen delivery via nasal cannula was tested at PF settings of 2.0 and 6.0, and SF rates of 2.0 and 6.0 L/min. A test lung simulated three breathing patterns representative of a chronic obstructive pulmonary disease patient at rest, during exercise, and while asleep. Volume-averaged fraction of inhaled oxygen (FiO2) was calculated by analyzing oxygen concentrations sampled at the exit of each replica and inhalation flow rates over time. POC pulse volumes were also measured using a commercial O2 conserver test system to attempt to predict FiO2 for PF. RESULTS Relative volume-averaged FiO2 using PF ranged from 68% to 94% of SF values, increasing with breathing frequency and tidal volume. Three of 15 replicas failed to trigger the POC when used with the sleep breathing pattern at the 2.0 setting, and four of 15 replicas failed to trigger at the 6.0 setting. FiO2 values estimated from POC pulse characteristics followed similar trends but were lower than those derived from airway replica experiments. CONCLUSION For the POC tested, PF delivered similar, though consistently lower, volume-averaged FiO2 than SF rates equivalent to nominal PF settings. Assessment of PF oxygen delivery using POC pulse characteristics alone may be insufficient; testing using airway replicas is useful in identifying possible cases of failure and may provide a better assessment of FiO2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

High Flow Nasal Cannulae versus Nasal Continuous Positive Airway Pressure in Neonates with Respiratory Distress Syndrome Managed with INSURE Method: A Randomized Clinical Trial

Background: In recent years, various noninvasive respiratory support (NRS) of ventilation has been provided more in neonates. The aim of this study was to compare the effect of HFNC with NCPAP in post-extubation of preterm infants with RDS after INSURE method (intubation, surfactant, extubation).Methods: A total of 54 preterm infants with RDS (respiratory distress syndrome) were enrolled in thi...

متن کامل

Comparison of Nasal Continuous Positive Airway Pressure Therapy with and without Prophylactic Surfactant in Preterm Neonates

Background: Preterm labor is at risk for respiratory distress syndrome (RDS) and sometimes requires to mechanical ventilation (MV) and surfactant therapy. Continuous positive airway pressure (CPAP) and Nasal Continuous positive airway pressure (NCPAP) are the methods of respiratory support especially for using in RDS of neonates. In other method surfactant is administered to babies via tracheal...

متن کامل

Heated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress

Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...

متن کامل

The Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP)

BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017