Interference between dental electrical devices and pacemakers or defibrillators: results from a prospective clinical study.

نویسندگان

  • Claude S Elayi
  • Stephanie Lusher
  • Jillian L Meeks Nyquist
  • Yousef Darrat
  • Gustavo X Morales
  • Craig S Miller
چکیده

BACKGROUND The authors aimed to determine whether electrical dental devices would interfere with the function of cardiac pacemakers or implantable cardioverter defibrillators (ICDs) in humans. METHODS The authors exposed asymptomatic nonpacemaker-dependent patients to commonly used electrical dental equipment (for example, battery-operated curing lights, ultrasonic baths, ultrasonic scalers, electric pulp testers, and electric toothbrushes) in an outpatient cardiology clinic. The authors operated dental devices at various distances and programmed cardiac devices to sense and pace. The authors obtained cardiac tracings using a cardiac programming unit and a cardiac provider who noted any interference interpreted the results in real time. RESULTS The authors enrolled 32 consecutive patients and tested 12 pacemakers and 20 ICDs. They did not observe any significant clinical interference in sensing and pacing functions in any patient; however, they noted minor interference without clinical impact in the telemetry from the cardiac programming unit during use of the ultrasonic scaler and bath. CONCLUSIONS The findings of this prospective study suggest that electrical devices commonly used in dental practices do not interfere with the sensing and pacing of contemporary cardiac patients' pacemakers or ICDs. However, they do interfere with the telemetry from the cardiac programming unit, without any clinical impact on patient safety. These findings should help in the development of clinical guidelines regarding dental management of patients with pacemakers or ICDs. PRACTICAL IMPLICATIONS Electrical dental devices (for example, ultrasonic baths, ultrasonic scalers) induced minor interference with programmers that interrogate cardiac devices implanted in patients; however, overall, dental devices do not appear to interfere with pacemakers' and defibrillators' pacing and sensing function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature

Background and Study Aims. Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices, the Food and Drug Administration and the manufacturer recommended not to use capsule endoscopy in these patients. The vast majority of investigations did not reveal any interference between capsule endoscopy and ca...

متن کامل

Interference Between Cellular Telephones and Implantable Rhythm Devices: A Review on Recent Papers

BACKGROUND Cardiac pacemakers and implantable defibrillators are potentially susceptible to electromagnetic interferences as they have complex circuitry for sensing and communication purposes. Cellular telephones being an important source of electromagnetic waves are likely to cause interference in the function of these devices. METHODS A systematic analysis of studies on interaction between ...

متن کامل

Irradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience.

AIMS AND BACKGROUND A prospective analysis was carried out on a group of irradiated patients with pacemakers or implantable cardioverter-defibrillators to identify any relationship between the various types of devices and physical and dosimetric parameters. Cardiac toxicity of the treatment was also investigated. METHODS AND STUDY DESIGN Forty-five irradiated patients, implanted with pacemake...

متن کامل

Interference in implanted cardiac devices, Part I.

Sensing intrinsic cardiac electrical activity is essential for the function of pacemakers and implantable cardioverter defibrillators (ICDs). Examples of undesired triggering or inhibition of pacemaker output by extraneous signals were identified early after the introduction of noncompetitive, “demand” pacemakers. Hermetic shielding in metal cases, filtering, and interference rejection circuits...

متن کامل

Do media players cause interference with pacemakers?

BACKGROUND Electrical devices generate electromagnetic fields that may interfere with pacemakers. Media players cause telemetry interference with pacemakers, but it is not known whether they cause direct interference with pacemakers. The purpose of this study was to examine the interaction between pacemakers and 3 different media players. METHODS In this prospective, randomized study, 54 pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Dental Association

دوره 146 2  شماره 

صفحات  -

تاریخ انتشار 2015