Amide proton signals as pH indicator for in vivo MRS and MRI of the brain - Responses to hypercapnia and hypothermia
نویسندگان
چکیده
Using proton MRS and MRI of mouse brain at 9.4T, this work provides the first in vivo evidence of pH-dependent concurrent changes of three amide signals and related metabolic responses to hypercapnia and hypothermia. During hypercapnia, amide proton MRS signals of glutamine at 6.8-6.9ppm and 7.6ppm as well as of unspecific compounds at 8.1-8.3ppm increase by at least 50% both at 37°C and 22°C. These changes reflect a reduced proton exchange with water. They are strongly correlated with intracellular pH which ranges from 6.75±0.10 to 7.13±0.06 as determined from a shift in creatine phosphokinase equilibrium. In MRI, saturation transfer from aliphatic as well as aromatic and/or amide protons alters slightly during hypercapnia and significantly during hypothermia. The asymmetry in magnetization transfer ratios decreased slightly during hypercapnia and hypothermia. Regardless of pH or temperature, saturation transfer from aliphatic protons between -2 and -4ppm frequency offset to water protons is significantly greater than that from aromatic/amide protons at corresponding offsets between +2 and +4ppm. Irradiation of aliphatic compounds at -3.5ppm frequency offset from water predominantly saturates lipids and water associated with myelin. Taken together, the results indicate that, for the B1 power used in this study, dipolar coupling between aliphatic and water protons rather than proton exchange is the dominant factor in Z-spectra and magnetization transfer ratio asymmetry of the brain in vivo.
منابع مشابه
MRS Shimming: An Important Point Which Should not be Ignored
Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...
متن کاملDetection of Glioblastoma Multiforme Tumor in Magnetic Resonance Spectroscopy Based on Support Vector Machine
Introduction: The brain tumor is an abnormal growth of tissue in the brain, which is one of the most important challenges in neurology. Brain tumors have different types. Some brain tumors are benign and some brain tumors are cancerous and malignant. Glioblastoma Multiforme (GBM) is the most common and deadliest malignant brain tumor in adults. The average survival rate for peo...
متن کاملCARDIOVASCULAR RESPONSES TO HYPERCAPNIA AND VARYING LEVELS OF ARTERIAL pH IN THE ANESTHETIZED CAT
Effects of acute hypercapnia on the cardiovascular system (CYS) were studied in the anesthetized cat. After surgery the animal was exposed to a gas mixture of 12% CO2 and 25% O2 in nitrogen, and hypercapnia with low levels of arterial pH (pHa) was produced for 20 minutes. In the second run the same level of hypercapnia was induced by ventilating the same cat from the above gas mixture but ...
متن کاملComparison between MRS and DWI in MRI of breast cancer
Introduction: Breast cancer is the most common cancer in women and is the second leading cause of cancer death (after lung cancer) in people throughout the world. Today, MRI is being used because of the limitations of x-ray mammography to detect breast cancer. Non-contrast sequences were associated to CE sequences in a breast MRI protocol for the sake of appraising morphologic ...
متن کاملMagnetic resonance spectroscopy of the brain under mild hypothermia indicates changes in neuroprotection-related metabolites.
Brain hypothermia has demonstrated pronounced neuroprotective effect in patients with cardiac arrest, ischemia and acute liver failure. However, its underlying neuroprotective mechanisms remain to be elucidated in order to improve therapeutic outcomes. Single voxel proton magnetic resonance spectroscopy ((1)H-MRS) was performed using a 7 Tesla MRI scanner on normal Sprague-Dawley rats (N=8) in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 133 شماره
صفحات -
تاریخ انتشار 2016