A Simple Sample Preparation with HPLC-UV Method for Estimation of Clomipramine from Plasma

نویسندگان

  • Sayed Abolfazl Mostafavi
  • Reza Tahvilian
  • Masoumeh Dehghani Poudeh
  • Zeinab Rafeepour
چکیده

Clomipramine is a tricyclic antidepressant. Different methods for determination of clomipramine hydrochloride in plasma have been described. Most of these procedures favor the use of acidic back-extraction in extraction procedure and HPLC as the analytical technique. In this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten the time of sample preparation considerably. Furthermore, the method was applied in bioequivalence study of new formulations of clomipramine in comparison with reference tablets. THE DRUG AND INTERNAL STANDARD WERE EXTRACTED FROM PLASMA WITH HEPTAN : isoamyl alcohol (95:5) and re-extracted with 200 μL of orthophosphoric acid (0.3% v/v). The organic layer was discharged and analysis was performed on C8 reverse phase ODS2 HPLC column with a mobile phase, acetonitrile : water (75:25) and UV detection set at 215 nm. Additionally, a single dose study was carried out with a two-sequence, crossover block-randomized design for bioequivalence study. Clomipramine tablets (3 × 25 mg) of either formulations (reference or test products) were administered separately in two occasions to 12 fasting healthy male volunteers. Blood samples were taken prior to and at 9 points within 48 h after dose administration. The retention time of internal standard (cisapride), clomipramine, and desmethyl clomipramine were 5.6 ± 0.2, 10.3 ± 0.3, and 9.5 ± 0.3 min, respectively. The standard curve covering the concentration ranges of 2.5-120 ng/mL was linear (r(2) = 0.9950 and 0.9979) for clomipramine and desmethyl clomipramine. The co-efficient of variation for intra-day and inter-day accuracy and precision was less than 18.3%. The pharmacokinetic parameters Cmax and Tmax were obtained directly from plasma clomipramine concentrations. Kel was estimated by log-linear regression and AUC was calculated by the linear trapezoidal rule. The pharmacokinetic parameters AUC and Cmax were tested for equivalence after log-transformation of data. The 90% standard confidence intervals of the mean values for the test/reference ratios, AUC, and Cmax were within the acceptable bioequivalence limits of 0.80-1.20. These results indicated that the analytical method was linear and accurate. Test and reference formulations were found to be bioequivalent and therefore interchangeable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple Sample Preparation with HPLC-UV Method for Estimation of Clomipramine from Plasma

Clomipramine is a tricyclic antidepressant. Different methods for determination of clomipramine hydrochloride in plasma have been described. Most of these procedures favor the use of acidic back-extraction in extraction procedure and HPLC as the analytical technique. In this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten t...

متن کامل

A Simple Sample Preparation with HPLC-UV Method for Estimation of Clomipramine from Plasma

Clomipramine is a tricyclic antidepressant. Different methods for determination of clomipramine hydrochloride in plasma have been described. Most of these procedures favor the use of acidic back-extraction in extraction procedure and HPLC as the analytical technique. In this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten t...

متن کامل

Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2010