Body-exhaust suit versus occlusive clothing. A randomised, prospective trial using air and wound bacterial counts.
نویسندگان
چکیده
We randomly allocated 50 total knee replacements to scrub teams wearing body-exhaust suits (BES) or Rotecno occlusive clothing. The effectiveness of the clothing was assessed using air andwound bacterial counts. Bacteria were recovered from 62% of wounds (64% BES, 60% Rotecno). The mean air count was 0.5 CFU/ m3 with BES and 1.0 CFU/m3 with Rotecno (p = 0.014). The mean wound counts were 14 bacteria/wound with BES and eight bacteria/wound with Rotecno (p = 0.171). There was no correlation between the air and wound counts (r = -0.011, Spearman's). The higher air counts suggest that Rotecno occlusive clothing is less effective than BES, but wounds were equally contaminated with both types of clothing suggesting that at very low levels of air contamination the contribution of bacteria to the wound from the air is irrelevant. Even doubling the air counts from 0.5 to 1.0 CFU/m3 had no detectable effect on the wound. This allows a reassessment to be made of other sources of contamination the effect of which would previously have been overwhelmed by contamination from air.
منابع مشابه
peri-operatively: a randomised trial
Background and objective Unintentional hypothermia of a patient is a common adverse effect during surgical procedures. Many strategies can be used to reduce heat loss. The aim of this prospective, randomised, controlled study was to determine whether the use of the thermal suit (T-Balance) could prevent surgical patients from experiencing thermal loss better than conventional measures. Methods ...
متن کاملComparison of three distinct clean air suits to decrease the bacterial load in the operating room: an observational study
BACKGROUND Lowering air-borne bacteria counts in the operating room is essential in prevention of surgical site infections in orthopaedic joint replacement surgery. This is mainly achieved by decreasing bacteria counts through dilution, with appropriate ventilation and by limiting the bacteria carrying skin particles, predominantly shed by the personnel. The aim of this study was to investigate...
متن کاملUltraviolet Radiation Compared to an Ultra - Clean Air Enclosure 813
Clean air in the operating room is important during joint replacement surgery. We compared monochromatic ultraviolet radiation of254 nm with the use ofa Charnley-Howorth air enclosure by bacterial air-sampling during 113 total hip arthroplasties. Air samples were taken continuously at the edge of the wound and every 15 minutes at a site 130 cm from the operating table. We also tested the effect...
متن کاملImproving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans.
The air quality in air-conditioned mass transport buses may affect bus drivers' health. In-bus air quality improvement with the voluntary participation of bus drivers by opening the exhaust ventilation fans in the bus was implemented in the Seventh Bus Zone of Bangkok Mass Transit Authority. Four bus numbers, including bus numbers 16, 63, 67 and 166, were randomly selected to investigate microb...
متن کاملComparison of three distinct surgical clothing systems for protection from air-borne bacteria: A prospective observational study
UNLABELLED BACKGROUND To prevent surgical site infection it is desirable to keep bacterial counts low in the operating room air during orthopaedic surgery, especially prosthetic surgery. As the air-borne bacteria are mainly derived from the skin flora of the personnel present in the operating room a reduction could be achieved by using a clothing system for staff made from a material fulfill...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 85 4 شماره
صفحات -
تاریخ انتشار 2003