The cornea in young myopic adults.
نویسندگان
چکیده
AIMS To further understand the effect of refractive error on the corneal dimensions and function. METHODS Corneal curvature, corneal thickness, and axial length measurements were performed, as well as specular microscopy and fluorophotometry, on patients with various refractive statuses. 216 subjects, mean age 22.2 (SD 4.2) years, were examined. Patients with previous contact lens wear history, external eye diseases, as well as previous ocular surgeries, were excluded. RESULTS The corneas were flatter in eyes with longer axial length (r = -0.22, p = 0.003). Eyes with more myopic spherical equivalent had longer axial length (r = -0.90, p <0.001) as well as less corneal endothelial density (r = 0.20, p = 0.037). Corneal endothelial density decreased in eyes with longer axial length (r = 0.24, p = 0.019); however, it correlated neither with corneal thickness (r = -0.06, p = 0.59) nor with corneal curvature (r = -0.07, p = 0.52). The corneas had a mean corneal thickness of 533 (SD 29) microm and were thinner in more myopic eyes (r = 0.16, p = 0.021). The corneas tended to be thinner in eyes with longer axial length. However, the correlation did not reach statistical significance (r = -0.11, p = 0.14). Besides, there was no significant correlation between the corneal thickness and the corneal curvature (r = -0.13, p = 0.093) and the endothelial permeability (r = 0.042, p = 0.69). The corneas with higher endothelial density had larger corneal transfer coefficient (r = 0.26, p = 0.024) and higher permeability to fluorescein molecules (r = 0.28, p = 0.014). Nevertheless, the corneal endothelial permeability did not correlate significantly with either the axial length (r = -0.18, p = 0.11) or the degree of myopia (r = 0.12, p = 0.26). CONCLUSION Changes in the anterior segments as the eyeball elongates in myopia progression included flatter corneal curvature, decreased corneal thickness, as well as decreased endothelial density. These factors should be considered in refractive surgery.
منابع مشابه
The Correlation of Differences in the Ocular Component Values with the Degree of Myopic Anisometropia
PURPOSE To determine the relationship between the differences in the ocular component values with the degree of anisomyopia. METHODS Refraction, corneal power (CP), and biometry were examined in 50 myopic adults with refractive differences (RD) over 1.50 diopters (D). Ocular components were measured by ultrasound biometry and keratometry. The correlation between the differences in the ocular ...
متن کاملCorrigendum: Corneal Power, Anterior Segment Length and Lens Power in 14-year-old Chinese Children: the Anyang Childhood Eye Study
To analyze the components of young Chinese eyes with special attention to differences in corneal power, anterior segment length and lens power. Cycloplegic refractions and ocular biometry with LENSTAR were used to calculate lens power with Bennett's method. Mean refraction and mean values for the ocular components of five different refractive groups were studied with ANOVA and post-hoc Scheffé ...
متن کاملWavefront aberrations in eyes of emmetropic and moderately myopic school children and young adults
Wavefront aberrations were measured using a psychophysical ray-tracing technique in both eyes of 316 emmetropic and moderately myopic school children and young adults. Myopic subjects were found to have greater mean root mean square (RMS) value of wavefront aberrations than emmetropic subjects. Emmetropic adults had the smallest mean RMS, which remained smaller than the values for myopic adults...
متن کاملTransient Axial Length Change during the Accommodation Response in Young Adults.
PURPOSE To measure the degree of transient axial elongation during the accommodation response in emmetropic and myopic young adults. To evaluate the effect of refractive error and accommodative demand on transient axial elongation of the eye. METHODS Axial length of the right eye was measured in 30 emmetropes and 30 myopes, by using the IOLMaster (Carl Zeiss Meditec, Inc., Dublin, CA), while ...
متن کاملToday’s PracTice refracTive fundamenTals
MyOPiC LASer COrreCtiOn The most popular type of laser correction for myopia is LASIK. Myopic laser correction is achieved by central corneal ablation, which reduces the refractive power of the anterior corneal surface. Myopic LASIK has been shown to be effective in correcting low to moderate myopia.1,2 LASIK correction of high myopia has been fraught with quality issues until recently. Factors...
متن کاملThe ocular biometric and corneal topographic characteristics of high-anisometropic adults in Taiwan.
BACKGROUND To investigate the difference of ocular biometric and corneal topographic characteristics between the two eyes in high anisometropes with difference of 4 D or more in spherical component. METHODS Fifty-one young anisometropic men were collected. Detailed ocular examinations, including cycloplegic autorefraction, best-corrected visual acuity, intraocular pressure, A-scan, and Orbsca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 85 8 شماره
صفحات -
تاریخ انتشار 2001