The microbubble or the microparticle?
نویسندگان
چکیده
DECOMPRESSION SICKNESS (DCS) has long been attributed to physical forces exerted by inert gas bubbles that may form in tissues, resulting in vascular occlusion and tissue disruption. Bubble formation occurs when a decrease in ambient pressure exceeds the rate at which soluble inert gas (e.g., nitrogen) can be eliminated from the tissues. Modern theory asserts that many signs and symptoms of DCS are due to complex vascular and other biological processes that occur in response to the bubbles, including inflammation and activation of coagulation, which lead to microvascular damage and thrombosis. Could it be that small biological vesicles are at the heart of the matter? In this issue of the Journal of Applied Physiology, Thom et al. (13) report that decompression stress in mice results in increased numbers of circulating microparticles (MPs), which they implicate in neutrophil activation and vascular injury. MPs are small (0.1–1 m) membrane vesicles shed in coordinated processes from the surface of a number of different cells in the vasculature. MPs are formed in response to stimuli that activate the cell or lead to apoptosis (5), and have proinflammatory and prothrombotic properties, making them candidates to mediate vascular injury in DCS. Thom and colleagues (13) report that MPs of platelet origin cause neutrophil activation and vascular injury, and that circulating neutrophils express high levels of antigens from other cell types, which they attribute to transfer from MPs. The findings reported in this study are quite novel, and if substantiated may improve our understanding of DCS. In addition to proposing pathogenic aspects for DCS, this paper reports several new observations about MP biology. This is the first report (to our knowledge) that individual MPs exhibit surface markers suggesting origin from multiple cells types. This finding could be explained by membrane fusion of MPs from various sources. Such a scenario has been proposed to explain otherwise enigmatic data in other settings, as for example in the case of the cellular origin of tissue factor bearing MPs in cancer (9). Second, the authors report that MPs expressing platelet surface markers interact with circulating neutrophils, leading to neutrophil degranulation and further MP production. Although other groups have reported the capacity of MPs to interact with and activate target cells (4), this paper proposes a novel mechanism by which MPs do this. Finally, and most importantly, the authors use innovative interventions to diminish MP concentrations in vivo and show that their approach attenuates decompression-induced intravascular neutrophil activation, neutrophil sequestration, and tissue injury. Recently, MPs derived from hematopoietic and vascular sources have been enumerated and characterized in a number of systemic illnesses with vascular pathobiology, including acute coronary syndromes, vasculitis, sepsis, and metabolic syndrome (6, 8). These small vesicles have been implicated in the pathophysiology of these diseases, although causation has yet to be unequivocally established. In this decompression stress model, Thom et al. (13) use two different approaches to diminish circulating MP levels in mice in vivo, and a third strategy to diminish platelet counts, which as expected, also resulted in reduced numbers of circulating platelet-derived MPs. This is the first report to experimentally test the importance of MPs using a depletion strategy. The data presented indicate successful reduction in MP counts in both the control and decompression-stressed mice, and assign causation by showing diminished injury in the treated animals. Broad application of an effective MP depletion strategy would allow investigation into the importance of MPs in a range of disease conditions and pathological processes. Thus it is important that the MP depletion strategies reported here be validated by other groups. The effectiveness of an antibody to annexin V for MP depletion is curious because it implies that circulating MPs have annexin V bound to their surface in vivo. A large proportion of MPs express negatively charged phosphatidylserine (PS) residues on their membrane surface, which allows ex vivo labeling techniques to take advantage of the affinity of annexin V for PS. The detection of appropriately sized particles that have bound fluorescently tagged annexin V is thereby utilized to differentiate MPs from background events using flow cytometry. It is not clear whether and to what degree endogenous annexin V binds to PS on the surface of MPs in the circulation, although another PS-binding protein—lactadherin—has been shown to associate with platelet-derived MPs in vivo (3). Moreover, MPs that fail to bind annexin V (presumably because they lack PS exposure) have been described both in vitro (10) and in vivo (1, 12); thus it is possible that an antibody to annexin V may deplete only a subpopulation of MPs that appear to be important to vascular injury in this decompression stress model. Flow cytometry is currently the most commonly used technique for enumerating and identifying cell parentage of microparticles, but there are several inherent technical challenges in studying these very small particles using instruments designed to investigate whole cells (11). There are marked differences in sensitivity of different flow cytometers, and the measurements are influenced by preanalytical practices in preparing and storage of plasma (11). These limitations have resulted in a broad range of reported “normal” numbers as well as cellular origin of plasma MPs. As a first step toward standardizing the measurement of MPs, the International Society of Thrombosis and Hemostasis recently published the result of a standardized flow cytometry protocol designed to enumerate platelet-derived MPs in human plasma (7). During this exercise, it was demonstrated that the ability of various flow cytometers to adequately discriminate particles of 0.5 m and 0.9 m was Address for reprint requests and other correspondence: M. S. Carraway, U.S. Environmental Protection Agency, Environmental and Public Health Division, CB 7315, Chapel Hill, NC 27599-7315 (e-mail: [email protected]). J Appl Physiol 110: 307–308, 2011; doi:10.1152/japplphysiol.01505.2010. Invited Editorial
منابع مشابه
Characterization of Microbubble-Based Drilling Fluids: Investigating the Role of Surfactants and Polymers
Colloidal Gas Aphrons (CGA), consist of gas bubbles with diameters ranging from 10 to 100 micron, surrounded by a thin aqueous surfactant film. This fluid combines certain surfactants and polymers to create the systems of microbubbles. The function of surfactant in CGAs is to produce the surface tension to contain the aphrons. Also, a biopolymer needs to be considered in the formulation as ...
متن کاملModeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)
Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...
متن کاملSelf-concentrating buoyant glass microbubbles for high sensitivity immunoassays.
Here, we report the novel application of a material with self-concentrating properties for enhancing the sensitivity of immunoassays. Termed as glass microbubbles, they are antibody functionalized buoyant hollow glass microspheres that simultaneously float and concentrate into a dense monolayer when dispensed in a liquid droplet. This self-concentrating charactaristic of the microbubbles allow ...
متن کاملDimensional Similarity in the Study of Microbubble Production Inside Venturi Tube
The present study considers of the water and air flow and Micro-Bubble production inside the venturi tube, by the use of dimensional analysis. Numerical analysis of Micro-Bubble creation in venturi tube requires fast computers and large amounts of storage space. Up to now, there has been no numerical analysis concerning Micro-Bubble creation and all other existing studies are experimental. To s...
متن کاملExperimental comparison of thermal neutron absorption cross section in nano and micro particles
The neutron collision cross-section is important in neutron use for a specific job, such as neutron therapy or even in nuclear reactors. In calculating computational codes such as MCNP, only information from the neutron-to-mass collision information contained in the computational code library is used, in the case of nanoscale particles in contrast to the mass of materials and / or particulate m...
متن کاملNew-onset seizure after perflutren microbubble injection during dobutamine stress echocardiography.
Intravenous microbubble contrast agents are frequently used during ultrasound imaging to improve endocardial border detection, enhance Doppler signals, differentiate thrombi from tumors or define vascular anatomy. Dobutamine stress echocardiography (DSE) with or without addition of atropine is a standard technique for evaluation of coronary artery disease. Noncontrast or contrast-enhanced DSE i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 110 2 شماره
صفحات -
تاریخ انتشار 2011