New concept in durability improvement of hip total joint endoprostheses.

نویسندگان

  • Lucian Capitanu
  • Virgil Florescu
  • Liliana-Laura Badita
چکیده

Starting from the well-known fact that the rolling movement always has a lower friction compared to sliding friction, the authors have conceived and realized a pivoting movement joint on a "layer of balls" with "compensation space", placed between the acetabular cup and the femoral head. This technical solution allows free self-directed migration of the balls, depending on the resistance opposed, with successive occupation of the "compensation space". As a concept, the proposed technical solution excludes the existence of a cage for maintaining the relative positions of the spheres. It can be observed that the smallest values of the force and of the friction coefficient are obtained for the prostheses with balls and self-directed movement (approximately 5 times smaller than the values obtained for a classical prosthesis). For all the couples tested, the friction force grows with the growth of the normal load and of the oscillation speed. Changing the contact mechanism for the artificial hip joint from one sliding contact between two large surfaces, to a multitude of rolling contacts, could lead to some problems regarding functionality and durability of the active prosthesis elements. The key to an accurate evaluation of damaging mechanisms acting on THP with self directed rolling balls is a clear and complete picture of the load transfer mechanism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear Testing of Total Hip Joints According to Iso and Development of a New Hip Joint Simulator According to Iso

INTRODUCTION The development of new, highly sophisticated materials for the articulating surfaces of total hip endoprostheses has led to an increasing demand for testing and verification. This includes tests and research regarding bio-compatibility, static load bearing capacity of the prostheses as well as tribological investigations. Since it has been found that wear debris play a dominant rol...

متن کامل

General Parametric Model of The Body of The Total Hip Endoprosthesis

The endoprostheses of the hip joint are the most commonly used group of implants in orthopedic surgery. The success of their application in the process of replacing natural hip joint with artificial depends, besides the patient related and surgical factors, which include the selection of the type of endoprosthesis and the extent of its adaptability to the patient. Because of that, endoprosthese...

متن کامل

استئوتومی انتهای فوقانی ران برای درمان استئوآرتریت مفصل ران

During the past 20 years, poximal femoral osteotomy has been forgotten because most orthopedic surgeon believed that total hip arthroplasty is the only treatment method for hip joint osteoarthritis. The disadvatages of proximal femoral osteotomy include: Uncertain results, prolonged rehabilitation time after surgery, little improvement in joint ROM and according tosome.euthors difficult subsequ...

متن کامل

Impact of overweight on the durability of Weller prostheses.

Background. The goal of our research was to assess overweight as a risk factor for reduced survivability of Weller-type artificial cement hip joints. Material and methods. We studied 71 patients (26 men, 45 women) diagnosed with aseptic loosening of Weller endoprostheses. The age of the patients ranged from 62 to 87 years of life (mean 74.3 +/- 6.0), the exploitation time of the artificial hip-...

متن کامل

Two-stage revision of implant-associated infections after total hip and knee arthroplasty

Septic loosening of total hip and knee endoprostheses gains an increasing proportion of revision arthroplasties. Operative revisions of infected endoprostheses are mentally and physically wearing for the patient, challenging for the surgeon and a significant economic burden for healthcare systems. In cases of early infection within the first three weeks after implantation a one-stage revision w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2014