Comparison of human brain metabolite levels using 1H MRS at 1.5T and 3.0T

نویسندگان

  • Fernando Fernandes Paiva
  • Maria Concepcion Garcia Otaduy
  • Ricardo de Oliveira-Souza
  • Jorge Moll
  • Ivanei Edson Bramati
  • Luciane Oliveira
  • Andrea Silveira de Souza
  • Fernanda Tovar-Moll
چکیده

Proton magnetic resonance spectroscopy (MRS) of the human brain has proven to be a useful technique in several neurological and psychiatric disorders and benefits from higher field scanners as signal intensity and spectral resolution are proportional to the magnetic field strength. OBJECTIVE To investigate the effects of the magnetic field on the measurement of brain metabolites in a typical routine clinical setting. METHODS Single voxel spectra were acquired from the posterior cingulate cortex in 26 healthy subjects. Each subject was scanned consecutively at 1.5T and 3.0T in a randomly distributed order. RESULTS SNR and peak width improvements were observed at higher fields. However, SNR improvement was lower than the theoretical two-fold improvement. Other than the values obtained for creatine (Cre) and myo-Inositol (mI), which were both higher at 3.0T, all metabolite concentrations obtained were roughly the same at both field strengths. All the metabolite concentrations were estimated with a Cramer Rao lower bounds (CRLB) lower than 15% of the calculated concentrations. CONCLUSIONS Even though the present study supports the expected benefits of higher field strength for MRS, there are several factors that can lead to different quantitative results when comparing 1.5T to 3.0T MRS. Future comparative studies are necessary to refine the metabolite thresholds for early detection and quantification of distinct neurological and psychiatric disorders using 3.0T MRS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 1.5T and 3T 1H MR Spectroscopy for Human Brain Tumors

OBJECTIVE We wanted to estimate the practical improvements of 3T proton MR spectroscopy ((1)H MRS) as compared with 1.5T (1)H MRS for the evaluation of human brain tumors. MATERIALS AND METHODS Single voxel (1)H MRS was performed at both 1.5T and 3T in 13 patients suffering with brain tumors. Using the same data acquisition parameters at both field strengths, the (1)H MRS spectra were obtaine...

متن کامل

Detection of Glutamate Alterations in the Human Brain Using 1H-MRS: Comparison of STEAM and sLASER at 7 T

PURPOSE To assess reproducibility of glutamate measurement in the human brain by two short echo time (TE) 1H-MRS sequences [stimulated echo acquisition mode (STEAM) and semi-localized by adiabatic selective refocusing (sLASER)] at 7 T. Reliable assessment of glutamate is important when studying a variety of neurological and neuropsychiatric disorders. At 7 T, the glutamate signal can be separat...

متن کامل

MR imaging of the fetal brain at 1.5T and 3.0T field strengths: comparing specific absorption rate (SAR) and image quality.

OBJECTIVES Our two objectives were to evaluate the feasibility of fetal brain magnetic resonance imaging (MRI) using a fast spin echo sequence at 3.0T field strength with low radio frequency (rf) energy deposition (as measured by specific absorption rate: SAR) and to compare image quality, tissue contrast and conspicuity between 1.5T and 3.0T MRI. METHODS T2 weighted images of the fetal brain...

متن کامل

Metabolic Alterations in Parkinson's Disease after Thalamotomy, as Revealed by 1H MR Spectroscopy

OBJECTIVE To determine, using proton magnetic resonance spectroscopy (1H MRS) whether thalamotomy in patients with Parkinson's disease gives rise to significant changes in regional brain metabolism. MATERIALS AND METHODS Fifteen patients each underwent stereotactic thalamotomy for the control of medically refractory parkinsonian tremor. Single-voxel 1H MRS was performed on a 1.5T unit using a...

متن کامل

Spinal Cord Diffusion Tensor Imaging (DTI) and 1H-MR Spectroscopy (MRS) at 1.5T and 3T

Introduction MRI is an important modality in the assessment of spinal cord (SC) diseases. Conventional examinations are based on anatomic T1 and T2-weighted images but new techniques such as Diffusion Tensor Imaging (DTI) and single-voxel 1H-MR spectroscopy (SV-MRS) tend to be used in order to better described the pathology and understand the underlying mechanisms. Several difficulties, includi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013