Possibility of differentiation of cochlear electrodes in radiological measurements of the intracochlear and chorda-facial angle position
نویسندگان
چکیده
Due to an increasing number of cochlear implantations, quality control has become more important. In addition to intraoperative biophysical measurements, radiological imaging is another possibility. An upcoming technique regarding this is Cone Beam CT (CBCT). Sixty-five data sets (35 Nucleus Contour Advance-Cochlear; 30 Flex Soft-MedEl) of postoperative imaging by CBCT (Accu-I-tomo F17, Morita, Kyoto, Japan) underwent further evaluation. Insertion angle, height of the cochlea, distance of the electrode to the medial or lateral wall, angle between chorda tympani and facial nerve and the precise position of the electrode cable in the facial-chordal angle were determined. The typical difference between the perimodiolar and lateral course of the electrodes could also be shown in radiological measurements. This demonstrates the accuracy and advantage of CBCT in visualisation of small structures with fewer metal artifacts. Furthermore, in 75% of patients, the angle of the chorda and facial nerve could be visualised. Significant differences in dependence of the electrode type for the relation of them to the facial nerve could be seen. In conclusion, CBCT achieves reliable visualisation and detailed imaging-based measurements of the intracochlear position of different cochlea electrodes. Additionally, clinically known differences can be reproduced. Even visualisation of the position of the electrode in the chorda-facial angle is possible. Therefore, CBCT is a useful tool in intra- and postoperative control of cochlear implants.
منابع مشابه
Radiological and Histological Evaluation of Perimodular Electrodes: Impact on Cochlear Implant Development
Introduction: Different Perimodiolar electrodes were developed by many cochlear implant (CI) manufacturers in the past few years. Possible advantages are lower stimulation thresholds and a better channel separation. A position close to the modiolus can be facilitated by different means: preformed electrode shape (Nucleus ContourTM electrode, Cochlear Corp., Australia), additional positioning el...
متن کاملTranscanal approach for implantation of a cochlear nerve electrode array.
OBJECTIVES/HYPOTHESIS To evaluate a transcanal approach for placement of a stimulating electrode array in the cochlear nerve. STUDY DESIGN Prospective cadaveric temporal bone study. METHODS Ten human cadaveric temporal bones were dissected. Both a facial recess approach with mastoidectomy and a transcanal approach using the novel technique were performed in each bone. A middle fossa dissect...
متن کاملSoft tissue facial profile and anteroposterior lip positioning in Iranians
Objective: Since orthodontic and orthognathic treatment planningin each ethnic group must be done according to the soft tissue facial characteristicsregarded as beauty,they thus vary from country to country.The main purpose of this articlewas to determine the mean range of the middle third of soft tissue facial profile and anteroposterior lip positioningusing 3angular and 2 linear measurement...
متن کاملEvaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...
متن کاملQuantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface
Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 36 شماره
صفحات -
تاریخ انتشار 2016