Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay
نویسندگان
چکیده
Some of the different currently applied approaches that correct presbyopia may reduce stereovision. In this work, stereo-acuity was measured for two methods: (1) monovision and (2) small aperture inlay in one eye. When performing the experiment, a prototype of a binocular adaptive optics vision analyzer was employed. The system allowed simultaneous measurement and manipulation of the optics in both eyes of a subject. The apparatus incorporated two programmable spatial light modulators: one phase-only device using liquid crystal on silicon technology for wavefront manipulation and one intensity modulator for controlling the exit pupils. The prototype was also equipped with a stimulus generator for creating retinal disparity based on two micro-displays. The three-needle test was programmed for characterizing stereo-acuity. Subjects underwent a two-alternative forced-choice test. The following cases were tested for the stimulus placed at distance: (a) natural vision; (b) 1.5 D monovision; (c) 0.75 D monovision; (d) natural vision and small pupil; (e) 0.75 D monovision and small pupil. In all cases the standard pupil diameter was 4 mm and the small pupil diameter was 1.6 mm. The use of a small aperture significantly reduced the negative impact of monovision on stereopsis. The results of the experiment suggest that combining micro-monovision with a small aperture, which is currently being implemented as a corneal inlay, can yield values of stereoacuity close to those attained under normal binocular vision.
منابع مشابه
Comparison of a hydrogel corneal inlay and monovision laser in situ keratomileusis in presbyopic patients: focus on visual performance and optical quality
PURPOSE To compare the visual performance and optical quality after Raindrop Near Vision Inlay implantation or monovision LASIK for the correction of presbyopia. MATERIALS AND METHODS In this retrospective case-series study, patients previously treated in the nondominant eye with monovision LASIK were compared with patients previously implanted with Raindrop Near Vision Inlay. The study enrol...
متن کاملReading performance after implantation of a small-aperture corneal inlay for the surgical correction of presbyopia: Two-year follow-up.
PURPOSE To evaluate the change in reading-performance parameters after implantation of the Kamra small-aperture intracorneal inlay over a 2-year follow-up. SETTING University Eye Clinic, Paracelsus Medical University, Salzburg, Austria. DESIGN Cohort study. METHODS This study comprised naturally emmetropic presbyopic patients. Bilateral reading acuity, reading distance, reading speed, and...
متن کاملStereoacuity after small aperture corneal inlay implantation
PURPOSE The aim of this study was to compare stereoacuity before and after KAMRA corneal inlay implantation for the correction of presbyopia. PATIENTS AND METHODS This is a prospective study of 60 patients who underwent KAMRA inlay implantation. Patients were examined before and 6 months after surgery for stereoacuity, uncorrected distance visual acuity (UDVA), and uncorrected near visual acu...
متن کاملComplete depigmentation of a small aperture corneal inlay implanted for compensation of presbyopia.
We describe a case of late-onset remarkable depigmentation of a small aperture corneal inlay implanted for presbyopia compensation. The patient was a participant in a clinical trial designed to evaluate the safety and efficacy of the AcuFocusTM ACU-10R160, which is a 10 µm-thick polyimide film tinted with an organic dye. Inlay implantation occurred under mechanical microkeratome Lasik flaps set...
متن کاملRefractive Surgical Correction Of Presbyopia With The Kamra Corneal Inlay
By Alois K. Dexl, MD, MSc Within the past few decades, various surgical procedures for the treatment of presbyopia have been implemented in cataract and refractive surgery. Recently introduced into the market was the Kamra corneal inlay (AcuFocus, Inc., Irvine, California). This inlay has the Conformité Europpeéne (CE) Mark and is currently commercially available in the European Union and other...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2013